Internal rj-45 cablerouting, Cabling and installing the aaps, Dressing the cables – Extron Electronics Hideaway Surface Access Products User Manual
Page 3: Internal rj-45 cable routing
3
Internal RJ-45 Cable
Routing
Cabling and Installing the AAPs
WARNING:
Ensure that AC power is disconnected before removing the front
panel.
1.
Remove and retain the four screws on the right and left sides of the front panel.
Lift the panel away from the enclosure.
CAUTION:
On the HSA 822, do NOT remove the center screws. They do not
fasten the AAP panel in place. They secure the AC power outlet.
2.
Secure each AAP to the panel with the provided #4-40 nuts.
3.
Route the AAP cables through the hole in the underside of the HSA and connect
them to the rear of the AAPs.
4.
Reinstall the front panel in the enclosure and secure it in place with the screws
removed in step 1.
Dressing the Cables
1.
Lift the HSA to extend the AAP cables to their maximum pull.
2.
Experiment with AAP cable positioning to ensure that the cables do not rub
against any edges and that the cable pull does not restrict the HSA lifting
movement. The figures below show the recommended cable routing.
3.
Route the cables as recommended in the photos below. Secure
the cables in the circled locations with the provided zip ties.
HSA 400
(shown w/ cables)
HSA 400
125 - 50/60 Hz 5A
Do not
Remove
Center
Screw
HSA 822
HSA 822
HSA 402 Rear View
HSA 822
View from
one side
Shown with clamshell removed
for clarity.
View from the opposite side
HSA 402
120-240 50/60 Hz 5A
120-240 50/60 Hz 5A
A1
A2
B1
B2
A1
A2
B1
B2
A B
A B
C D
C D
HSA 822
HSA 400 / HSA 402
Present on
HSA 402 Only
Present on
HSA 402 Only