beautypg.com

Specifications – Extron Electronics FOX DA8 User Guide User Manual

Page 20

background image

Specifications

Optical Specifications

NOTE: These amplifiers are class 1 laser products. They meet the safety regulations of IEC-60825, FDA8 21

CFR 1040.10, and FDA8 21 CFR 1040.11.

Number/type

Input .................................. 1 singlemode or multimode fiber optic
Output ............................... 8 singlemode or multimode fiber optic

Connectors .................................... 8 LC connectors
Operating distance

Singlemode ........................ 30 km (18.75 miles) with singlemode (SM) cables with an Extron singlemode Tx/Rx unit
Multimode ....................... 300 m (985’) with 62.5 µm multimode (MM) cables with an Extron multimode Tx/Rx unit

1 km (3280’) with 50 µm multimode (MM) cables with an Extron multimode Tx/Rx unit
2 km (6561’) with 50 µm 2000 MHz bandwidth laser multimode cable with an Extron
multimode Tx/Rx unit

NOTE: Operating distance is approximate. These are typical distances. The maximum distance may be greater than

these typical numbers depending on factors such as fiber type, fiber bandwidth, connector splicing, losses,
modal or chromatic dispersion, environmental factors, and kinks.

Nominal peak wavelength .............. 850 nm for MM model,

1310 nm for SM model

Data rate ........................................ 4.25 Gbps
Transmission power

Singlemode ........................ -5 dBm, typical
Multimode ......................... -5 dBm, typical

Maximum receiver sensitivity

Singlemode ........................ -18 dBm, typical
Multimode ......................... -12 dBm, typical

Optical loss budget

Singlemode ........................ 13 dB, maximum
Multimode ......................... 7 dB, maximum

Control/Remote

Serial control ports ......................... 1 RS-232, 3.5 mm captive screw connector, 3 pole (rear panel)

1 RS-232, 2.5 mm mini stereo jack (front panel)

Baud rate and protocol ................... 9600 baud, 8 data bits, 1 stop bit, no parity
Serial control pin configurations ..... Captive screw connector: 1 = TX, 2 = RX, 3 = GND

Mini stereo jack: tip = TX, ring = RX, sleeve = GND

Program control ............................. Extron control/configuration program for Windows

®

Extron Simple Instruction Set (SIS

)

Extron FOX DA8 • Specifications

14