Timeout

Pauses of 10 seconds or longer between command ASCII characters result in a timeout. The
command operation is aborted with no other indication.

Using the Command and Response Table

The

Command and Response Table for SIS Commands

is on page 10.

Lower case letters

are acceptable in the command field.

Symbols are used throughout the table to represent

variables in the command/response fields. Command and response examples are shown
throughout the table. The following ASCII to HEX conversion table (see

figure 6

) is for use

with the command and response table.

ASCII to HEX Conversion Table

Figure 6.

ASCII to HEX Conversion Table

Symbol Definitions

The following symbols (variables) are used in the

command and response table

. The

symbols represent variables in the unit-initiated messages and the command and response
table fields.

]

= CR/LF (carriage return/line feed)

= space

X!

= Output

1 through 8

X@

= Mute status

0 = off (unmuted)

1 = on (muted)

X#

= Firmware version

Vx.xx

X$

= Transceiver module status

00000000 = no light input

10000000 = light input

X%

= Temperature

nnn

F = whole degree Fahrenheit

X^

= Transceiver module status

0 = no module installed

1 = multimode

2 = singlemode

Extron FOX DA8 • Remote Control