Installation, cont'd, Installing the maaps and the cables, Installing the cpm enclosure – Extron Electronics CPM208 User Manual
Page 8: Das 101c m a udio buff er
CMP200 and CMP208 • Installation
Installation, cont'd
CMP200 and CMP208 • Installation
4.
From the underside of the table, reinstall the mounting
brackets on the enclosure (figure 2-2), then tighten the
brackets to secure the enclosure to the surface.
Installing the MAAPs and the Cables
Each CPM unit ships with one (CPM200) or two (CPM208)
MAAP shelves. The MAAP shelf in the CPM200 supports three
MAAPs. Both MAAP shelves in the CPM208 support four
MAAPs. The shelves are installed at the factory in either the
upper position (recessed 1” from the top), or the lower position,
(recessed 2.5” from the top).
The upper position is suitable for use with A/V and active
connector modules and the lower position is suitable for captive
cable installations where the cables are permanently installed
in the connector bay and are pulled out as needed. If your
application requires the MAAP shelves to be installed in a
different position, the shelves must be moved.
Moving the MAAP shelf in the CPM200
Move the MAAP shelf in the CPM200 as follows:
1.
Remove the hex screws securing any MAAPs to the MAAP
shelf, then remove the MAAPs from the enclosure.
2.
Remove the four Philips screws securing the MAAP shelf
to the MAAP shelf brackets, then remove the MAAP shelf
from the enclosure.
3.
Remove the four MAAP shelf brackets from the enclosure.
4.
Reinstall the four MAAP shelf brackets in the desired
position (leave the brackets slightly loose until the shelf is
installed).
5.
Gently insert the shelf into the CPM enclosure until it rests
on the MAAP shelf brackets.
6.
When the shelf contacts the shelf bracket, align the screw
holes and install the four screws to secure the shelf to the
shelf brackets.
7.
Tighten the MAAP shelf bracket screws.
Moving the MAAP shelves in the CPM208
Move the MAAP shelves in the CPM208 as follows:
1.
Remove the hex screws securing any MAAPs to the MAAP
shelves, then remove the MAAPs from the enclosure.
2.
Loosen, then remove the four Philips screws holding
each MAAP shelf in the enclosure, then move the MAAP
shelves to the desired position within the enclosure.
Installing the CPM Enclosure
1.
Remove the mounting brackets (2 on the CPM200 and 4 on
the CPM208) on the sides of the enclosure.
2.
If necessary, move the MAAP shelves to the lower position
(optional) from the upper (default) position within the
CPM unit. See the section on "Installing the MAAPs and
the Cables" on the following page.
The upper position is designed for applications using
A/V and active connector MAAP modules. The lower
position is designed for use with cable slot (split) module
plates and is used for captive cable installations where
cables are permanently installed in the CPM enclosure
and pulled out as needed.
Mounting
Surface
Mounting Bracket
Extron
CPM200
Modular A/V
Connecter Bay
DAV
101C
M
VGA
Lin
e Dri
ver
Vid
eo In
put Pow
er
DAS
101C
M A
udio
Buff
er
Figure 2-2 — CPM200 enclosure installation
3.
Carefully lower the CPM enclosure into the hole to test the
fit. If necessary, remove the enclosure and use a file or rasp
to enlarge or smooth the edges of the opening.