beautypg.com

Rs-232/remote contr ol, cont ’d, Timeout, Using the command/r esponse table – Extron Electronics CD 900 User Manual

Page 14

background image

CD 900 Decoder

RS-232/Remote Control

RS-232/Remote Contr

ol, cont

’d

CD 900 Decoder


RS-232/Remote Control

E01 -

Invalid input channel number (out of range)

E06

-

Auto-switch active (DIP switch 1 in enable position)

E10 -

Invalid

command

E13 -

Invalid value (out of range)

Timeout

Pauses of 10 seconds or longer between command

ASCII

characters r

esult in a timeout. The command operation is

aborted with no other indication.

Using the command/r

esponse table

The command/r

esponse table is on the next page. Lower case

letters ar

e allowed in the command field only as indicated.

Symbols used thr

oughout the table to r

epr
esent variables in the

command/r

esponse fields. Command and r

esponse examples

ar

e shown thr

oughout the table. The

ASCII to HEX conversion

table below is for use with the command/r

esponse table.

Symbol definitions

=

CR/LF (carriage r

eturn/line feed) (0x0D 0A)

=

space

X1

=

Input

number

1 or 2

X2

=

Color/tint/contrast

value

1 - 127

X3

=

0 or 1

0 (of
f) or 1 (on)

X4

=

Input

type

0 = no input

1 = NTSC 3.58

2 = P

A

L

3 = NTSC 4.43

4 = SECAM

X5

=

Softwar

e version

x.xx

X6

=

Horizontal shift value

1

-

63

ASCII to HEX Con

ver

sion

T

a

b

le

4-4

4-5

COMMAND/RESPONSE TABLE
Description

Command

Response

Notes

ASCII

HEX

to host

Input selection
Select input

X1

2!

32•21

C2

Select input 2

Picture controls
Set color value to

X2

X2

C

X2

43

Col

X2

Set color value to

X2

Increment color value

{C

7B 43

Col

X2

Previous color value +1

Decrement color value

}C

7D 43

Col

X2

Previous color value -1

Set tint value to

X2

X2

T

X2

54

Tin

X2

Set tint value to

X2

Increment tint value

{T

7B 54

Tin

X2

Previous tint value +1

Decrement tint value

}T

7D 54

Tin

X2

Previous tint value -1

Set contrast value to

X2

X2

^

X2

5E

Con

X2

Set contrast value to

X2

Increment contrast value

{^

7B 5E

Con

X2

Previous contrast value +1

Decrement contrast value

}^

7D 5E

Con

X2

Previous contrast value -1

Horizontal shift
Set H shift value to

X6

X6

H

X6

48

Hph

X6

Set horizontal shift value to

X6

Increment H shift value

{H

7B 48

Hph

X6

Previous horizontal shift value +1

Decrement H shift value

}H

7D 48

Hph

X6

Previous horizontal shift value -1

Information, part number, and firmware requests
Information request

I/i

49/69

C

X1

•T

X4

•Col

X2

•Tin

X2

•Con

X2

•Hph

X6

•Frz

X3

Input 2; NTSC 3.58; color - 165;

C2•T1•Col65•Tin70•Con100•Hph39•Frz0

tint -70; contrast - 100; H shift - 39;
freeze off

Request for part number

N/n

4E/6E

N60-355-01

60-355-01 = CD 900

Query software version

Q/q

51/71

QVER•

X5

Software version

X5