Rs-232/remote contr ol, cont ’d, Timeout, Using the command/r esponse table – Extron Electronics CD 900 User Manual
Page 14

CD 900 Decoder
•
RS-232/Remote Control
RS-232/Remote Contr
ol, cont
’d
CD 900 Decoder
•
RS-232/Remote Control
E01 -
Invalid input channel number (out of range)
E06
-
Auto-switch active (DIP switch 1 in enable position)
E10 -
Invalid
command
E13 -
Invalid value (out of range)
Timeout
Pauses of 10 seconds or longer between command
ASCII
characters r
esult in a timeout. The command operation is
aborted with no other indication.
Using the command/r
esponse table
The command/r
esponse table is on the next page. Lower case
letters ar
e allowed in the command field only as indicated.
Symbols used thr
oughout the table to r
epr
esent variables in the
command/r
esponse fields. Command and r
esponse examples
ar
e shown thr
oughout the table. The
ASCII to HEX conversion
table below is for use with the command/r
esponse table.
Symbol definitions
=
CR/LF (carriage r
eturn/line feed) (0x0D 0A)
•
=
space
X1
=
Input
number
1 or 2
X2
=
Color/tint/contrast
value
1 - 127
X3
=
0 or 1
0 (of
f) or 1 (on)
X4
=
Input
type
0 = no input
1 = NTSC 3.58
2 = P
A
L
3 = NTSC 4.43
4 = SECAM
X5
=
Softwar
e version
x.xx
X6
=
Horizontal shift value
1
-
63
ASCII to HEX Con
ver
sion
T
a
b
le
4-4
4-5
COMMAND/RESPONSE TABLE
Description
Command
Response
Notes
ASCII
HEX
to host
Input selection
Select input
X1
2!
32•21
C2
Select input 2
Picture controls
Set color value to
X2
X2
C
X2
43
Col
X2
Set color value to
X2
Increment color value
{C
7B 43
Col
X2
Previous color value +1
Decrement color value
}C
7D 43
Col
X2
Previous color value -1
Set tint value to
X2
X2
T
X2
54
Tin
X2
Set tint value to
X2
Increment tint value
{T
7B 54
Tin
X2
Previous tint value +1
Decrement tint value
}T
7D 54
Tin
X2
Previous tint value -1
Set contrast value to
X2
X2
^
X2
5E
Con
X2
Set contrast value to
X2
Increment contrast value
{^
7B 5E
Con
X2
Previous contrast value +1
Decrement contrast value
}^
7D 5E
Con
X2
Previous contrast value -1
Horizontal shift
Set H shift value to
X6
X6
H
X6
48
Hph
X6
Set horizontal shift value to
X6
Increment H shift value
{H
7B 48
Hph
X6
Previous horizontal shift value +1
Decrement H shift value
}H
7D 48
Hph
X6
Previous horizontal shift value -1
Information, part number, and firmware requests
Information request
I/i
49/69
C
X1
•T
X4
•Col
X2
•Tin
X2
•Con
X2
•Hph
X6
•Frz
X3
Input 2; NTSC 3.58; color - 165;
C2•T1•Col65•Tin70•Con100•Hph39•Frz0
tint -70; contrast - 100; H shift - 39;
freeze off
Request for part number
N/n
4E/6E
N60-355-01
60-355-01 = CD 900
Query software version
Q/q
51/71
QVER•
X5
Software version
X5