Mounting the 3g hd-sdi 101, Tabletop placement, Ul guidelines for rack mounting – Extron Electronics 3G HD-SDI 101 User Guide User Manual
Page 7: Rack mounting
3G HD-SDI 101 • Installation and Operation
3
Mounting the 3G HD-SDI 101
The small size of this extender allows it to be mounted on a
tabletop, on a rack, or under furniture.
N
The 3G HD-SDI 101 is designed be placed at the end of a
long cable run and close to the display device.
Tabletop placement
Attach the four included rubber feet to the bottom of the unit
and place it in any convenient location.
Rack Mounting
UL guidelines for rack mounting
The following Underwriters Laboratories (UL) guidelines are
relevant to the safe installation of the 3G HD-SDI 101 in a rack:
1
.
Elevated operating ambient temperature —
If the unit
is installed in a closed or multi-unit rack assembly, the
operating ambient temperature of the rack environment
may be greater than room ambient temperature. Therefore,
install the equipment in an environment compatible with
the maximum ambient temperature (Tma: +122 °F, +50 ° C)
specified by Extron.
2
.
Reduced air flow —
Install the equipment in the rack
so that the equipment gets adequate air flow for safe
operation.
3
.
Mechanical loading —
Mount the equipment in the rack
so that uneven mechanical loading does not create a
hazardous condition.
4
.
Circuit overloading —
Connect the equipment to
the supply circuit and consider the effect that circuit
overloading might have on overcurrent protection and
supply wiring. Give appropriate consideration to the
equipment nameplate ratings.
5
.
Reliable earthing (grounding) —
Maintain reliable
grounding of rack-mounted equipment. Pay particular
attention to supply connections other than direct
connections to the branch circuit (such as power strips).