beautypg.com

3g hd-sdi 101 operation – Extron Electronics 3G HD-SDI 101 User Guide User Manual

Page 11

background image

3G HD-SDI 101 • Installation and Operation

7

3G HD-SDI 101 Operation

To operate the 3G HD-SDI 101 cable equalizer, follow these

instructions:
1.

Mount the 3G HD-SDI 101 in a convenient location at the

end of a long cable run and close to the display device.

2.

Connect the power supply (provided) to the equalizer,

using the captive screw connector. Ensure the connections

have the correct polarity as shown in the illustration

below:

12V

0.2A MAX

POWER

Power Receptacle

DC Power Cord

Captive Screw
Connector

For connections to captive screw receptacles, the length of the

exposed wires is critical.

N

The ideal length of stripped wire is 3/16" (5 mm):

If the stripped section of wire is longer than 3/16",

the exposed wires may touch, causing a short circuit
between them.
If the stripped section of wire is shorter than 3/16",

the wires can be easily pulled out even if tightly
fastened by the captive screws.

C

Do not tin the wires. Tinned wire does not hold its

shape and can become loose over time.

3.

Use a BNC connector to connect the input signal from the

source.

All input signals are equalized.

Input signals at 270 MHz, 1.485 GHz, or 2.97 GHz are

re-clocked. Signals at other rates are passed through

without re-clocking.

4.

Use a BNC connector to connect the output signal to the

display device.

Power Supply

Output Cord

SECTION A–A

Ridges

Smooth

A

A