beautypg.com

Before installation, Caution – John Wood Noritz N-069M-DV User Manual

Page 69

background image

69

2.

Before Installation

Caution

Compatibility Check

• Make sure that the vent terminal is compatible with the product it will be installed with. If an

improper terminal is used, a fire hazard will be created.

Choosing Installation Site

• Maintain the proper clearances to combustibles

The heat and moisture from the water heater may cause corrosion of aluminum materials.

• Install the vent terminal so that it is easily accessible for maintenance from both the indoors and the

outdoors.

• Install the vent terminal so that all exhaust is directed to and all intake air is taken from the outdoors.
• Steam or condensed water may drip out of the vent terminal. Dispose of this condensed water

according to local codes and in order to prevent injury or property damage.

Check Wall Thickness

• This vent terminal model has four different sizes. Choose the correct model to fit the thickness of

the wall that the terminal will pass through.

Model name

Wall thickness

VT4-TS-5

3.5" to 5"

VT4-TS-8

5" to 8.5"

VT4-TS-14

8.5" to 15"

VT4-TS-27

15" to 27"

SAR8192-2_068_073_E_J.p65

05.11.29, 9:01 PM

Page 69

Adobe PageMaker 6.5J/PPC