Installation Clearances

Before installing, check for the following:

Install in accordance with relevant building and mechanical codes, as well as any local, state
or national regulations.

Item

Distance from combustibles

• Maintain the following clearances

from both combustible and
non-combustible materials.

• There must be a clearance of 24" or

more in front of the Flue terminal.

• This restriction will not be applied to an

area where an effective shield makes a
clearance of 24" or more in front of the
exhaust outlet.

Check

Illustration

Caution

• If possible, leave 8" or more on either

side of the unit to facilitate inspection.

• If possible, leave 24" or more in front of

the unit to facilitate maintenance
and service if necessary.

Securing of space for

repair/inspection

24" or
more

8" or
more

8" or
more

Outdoor Clearances to Opening

into Any Building

Distance from
the top surface

Distance from
the side

12"

or

more

2" or

more

Consult vent
manufacturer
for clearances

12"
or more

12" or
more

12" or
more

There must be no
building opening
within this area.

12" or
more

Flue terminal