beautypg.com

Troubleshooting faq, Troubleshooting-1, Initial operation – John Wood Noritz N-069M-DV User Manual

Page 21: Temperature

background image

21

Troubleshooting-1

Initial Operation

Unit does not attempt to ignite
when water is running.

• Is water running?

• Check for reversed plumbing or crossed pipes.

• Check the water drain valve filter. (

p.20 )

• Reset unit and try again. There may be air in the gas line.

• Have a professional check the gas supply pressure.

Unit attempts to ignite but fails

Temperature

Hot water is not available
when a fixture is opened.

• Are the gas and water supply valves fully open?

• Is the water supply cut off?

• Is the hot water fixture sufficiently open?

• Is the gas being cut off by the gas meter ?

(Can other gas devices such as stoves be used?)

• (For LP) Is there enough gas in the tank?

(Can other gas devices such as stoves be used?)

• Is the water drain valve filter clogged? (

p.20)

• Is the power button turned on?

• Are the gas and water supply valves fully open?

• Is the water temperature setting appropriate?

(

p.12 and p.13)

• If the water supply temperature is high, it is possible
for the temperature to be higher than the temperature
set on the remote controller.
• If only a small amount of hot water is demanded, it is
possible for the temperature to be higher than the
temperature set on the remote controller.
• If the supply water goes through a solar pre-heating
system, it is possible for the temperature to be higher
than the temperature set on the remote controller.

The water is too hot.

• Have you allowed enough time for the cold water in the

pipes to drain out?

• Is the water supply cut off?

• Is the heater frozen?

• Is the hot water fixture sufficiently open?

No water is available when
a fixture is opened.

The hot water is not the correct
temperature.

Water takes time to become hot
when turning the hot water fixture.

SAR8192-2_014_026_E_J.p65

05.11.29, 9:01 PM

Page 21

Adobe PageMaker 6.5J/PPC