beautypg.com

Installation, Maintenance – John Wood Superflue Power Vent (75 Gallon) User Manual

Page 32

background image

Installation

The heating mode may be one of the following options:
A

A fan coil (air handler)

B

A hydronic baseboard (finned tube) loop/In-floor heating

Fan Coil

The following is a list of requirements for the installation of
the heating loop to the water heater (see Figure 28).
1. Install shut-off valves and unions so that the water

heater can be isolated from the heating module should
servicing of the water heater become necessary.

2. Install a drain valve at the lowest point of the heating

loop so that water can be drained from the heating mod-
ule without affecting the water heater.

3. If the air handler does not have a venting means at the

highest point of the piping arrangement, install an air
bleed at the highest point of the plumbing arrangement.

Baseboard Radiator Heating

The following is a list of requirements for the installation of
the heating loop to the water heater (see Figure 29).
1. Install shut-off valves and unions so that the water

heater can be isolated from the heating module should
servicing of the water heater become necessary.

2. A drain valve must be installed at the lowest point of the

heating loop so that water can be drained from the heat-
ing module without affecting the water heater.

3. Install air bleed valves at the highest points to purge air

from the system.

Maintenance

The installation and maintenance of the water heater must
follow all of the instructions described in sections I to VII of
this manual. Heater failure that is a result of the heating sys-
tem is not covered by warranty.

– 32 –

SIDE-TAPPED PIPING OF GSW
POWER-VENTED GAS-FIRED
WATER HEATERS (INTERNAL
OR EXTERNAL CIRCULATOR)

IF USED CHECK VALVE
REQUIRES EXPANSION TANK

COLD SUPPLY

EXPANSION TANK
(OPTIONAL)

MIXING
VALVE

M

H

C

300mm (8 in.)

MAX.

HOT

OUTLET

COLD INLET

SUPPLY

RETURN

WATER

HEATER

DRAIN PURGE V

A

LV

E

INTERNAL

CIRCULA

TO

R

EXTERNAL

CIRCULATOR

CHECK
VALVE

HOSE BIB

(OPTIONAL)

AIR HANDLER

HOT

W

A

TER T

O

HOUSE FIXTURE

HYDRONIC BASEBOARDS

(SERIES CONNECTED SHOWN)

HOT

W

A

TER T

O

HOUSE FIXTURE

EXPANSION TANK
(OPTIONAL)

MIXING
VALVE

M

H

C

BASEBOARD PIPING OF
GSW POWER-VENTED
GAS-FIRED WATER
HEATERS (SIDE-TAPPED)

FLOW CONTROL

FLOW CONTROL

Figure 28 Combo Heating - Air Handler

Figure 29 Combo Heating - Baseboard

IF USED CHECK VALVE
REQUIRES EXPANSION TANK

COLD SUPPLY

300mm (8 in.)

MAX.

HOT

OUTLET

COLD INLET

SUPPL

Y

RETURN

WATER

HEATER

CIRCULATOR

CHECK
VALVE

HOSE BIB

(OPTIONAL)