John Wood Superflue Power Vent (75 Gallon) User Manual
Page 20
Installation Checklist
– 20 –
Check Here
1.
Have the safety precautions described in this
manual been implemented?
2.
Does the gas piping conform to the recom-
mendations of your Gas Utility Company?
3.
Has the gas piping been tested?
4.
Is the supply pressure correct?
5.
Is the water heater connected to the correct
gas supply as shown on the rating plate
(Natural Gas/Propane)
6.
Is the clearance between the water heater and
combustible construction as per specifica-
tions?
7.
Is the water piping correctly connected? Are
you certain that there are no leaks?
8.
Is the water heater filled with water?
9.
Is the cold water supply valve open?
10.
Is the vent pipe installed properly and are the
vertical and horizontal runs properly support-
ed?
11.
Is the vent hood air intake opening unobstruct-
ed?
12.
Is the T&P valve installed? Is the drain pipe
from the T&P valve unobstructed?
13.
Is a drain pan installed (if required) with a prop-
er overflow pipe, directed to a drain?
14.
Have you taken steps to prevent water damage
in case of leaks?
15.
Is the electric supply a 120V, electrically
grounded, 15A fused, correct polarity circuit?
16.
Does the area around the water heater have
adequate ventilation?
If the answer to all of the questions
above is “Yes”, read the Operating
Instructions and proceed with lighting
the heater.