Figure 20 gas valve/temperature control – John Wood Superflue Power Vent (75 Gallon) User Manual

Page 19

background image

• Fill the tank with water and check all connections for

leaks. Open the nearest hot-water faucet and let it run
for 3 minutes to purge the water lines of air and sedi-
ment and to ensure complete filling of the tank. The
electrical power may then be turned on. Verify proper
operation after servicing.

Note: Always reference the wiring diagram for the correct
electrical connections.

– 19 –

GAS CONTROL

SIDE VIEW

QUICK CONNECTS FOR

POWER SUPPLY AND IGNITER

LOCATED ON UNDERSIDE

OUTLET

PRESSURE

PORT

MANIFOLD PRESSURE

ADJUSTMENT (REMOVE

CAP FOR ACCESS)

3/4” NPT. WRAP

WITH TEFLON TAPE

(2 WRAPS MIN.)

GROUND

CONNECTION

GAS CONTROL

FRONT VIEW

GAS OUTLET

TO BURNER

GAS INLET

1/2” NPT

TEMPERATURE

ADJUSTMENT

BUTTONS

TEMPERATURE

INDICATORS

IGNITER AND FLAME

PROBE ASSEMBLY

COMBUSTION

BLOWER

AIR

PRESSURE

SWITCH

HIGH
LIMIT

SWITCH

TO POWER SUPPLY

DISCONNECT AND

OVERLOAD

PROTECTION

WHITE

BLACK

GREEN

INTELLI-VENT

TM

CONTROL

BOTTOM VIEW

Figure 21 Gas Control/Thermostat Details and Wiring Diagram (White-Rodgers)

CONNECTOR

GREEN

MAXIMUM SUPPLY INLET PRESSURE
14.0 in. w.c. (3.5kPa) ALL GASES

THIS GAS CONTROL IS EQUIPPED WITH AN ECO (ENERGY CUT-OFF)
THE ECO WILL SHUT THE GAS OFF SHOULD THE OUTLET WATER
TEMPERATURE EXCEED 93° (200°F)

SUPPLY INLET
PRESSURE PORT

SUPPLY GAS
INLET 1/2” NPT

MANIFOLD CON-
NECTION UNDER
CONTROL

MANIFOLD PRESSURE
PORT UNDER CONTROL

LED INDICATOR

BURNER MANIFOLD
PRESSURE ADJUST-
MENT (REMOVE
DIAL FOR ACCESS

SAFETY
COVER

INCREASE
PRESSURE

DECREASE PRESSURE

GAS CONTROL VIEWED FROM GAS INLET
WITH TEMPERATURE DIAL REMOVED

Figure 20 Gas Valve/Temperature Control

BURNER MANIFOLD GAS PRESSURE

NATURAL GAS

3.5 in. w.c. (0.9kPa)

PROPANE GAS 10.0 in. w.c. (2.5kPa)

SUPPLY INLET GAS PRESSURE

NATURAL GAS

7.0 in. w.c. (1.7kPa)

PROPANE GAS 11.0 in. w.c. (2.7kPa)

GAS CONTROL SWITCH
GAS VALVE CONNECTOR

GAS VALVE
CONNECTOR

GND

QUICK CONNECTORS
MAIN AND IGNITER
PRESSURE SWITCH
AND INDUCER

GAS CONTROL/THERMOSTAT - VIEW OF ELECTRICAL
CONNECTIONS, WITH COVER REMOVED (WDER 2000N)