beautypg.com

Global water – Xylem AD200-1 VOICE ALARM AUTODIALERS User Manual

Page 12

background image

Global Water

800-876-1172

• globalw.com

- 12 -

8. The AD200-1 will sequentially dial the programmed Locations (1-4). If

there is no number stored in a location, it will be skipped. The OGM will
be delivered when the AD200-1 receives an answer. (The OGM will not
be played through the speaker.) For pager numbers, the pager code will be
transmitted instead of an OGM.

9. The AD200-1 will automatically go through the next programmed location

repeating the same process.

c) The AD200-1 is now ready for operation.

Utilizing the EEPROM and CPU memory cell components, the AD200-1 will
retain its’ memory in the event of a power loss. The internal 9-volt battery will
provide stand by power for approximately 4 hours of operation. If more battery
backup is needed, an optional rechargeable power pack (GLOBAL WATER part#
PP- 1) is available and plugs into the AD200-1, providing up to 24 hours of stand
by power.