J

E

B

B

F

6. Using a spanner wrench (J),

tighten the module to approximately
12 lbf•ft (16 N•m).

Note: spanner wrenches are available
from Hoffman Specialty.
Specify part no. 600209.

3. Using a 3/4” (19mm) socket wrench,

remove and discard the seat (E) from
the trap body (B).

4. Using a scraper, remove any scale or

debris inside the trap body (B) especially
around the seat area (F). Do not scratch
seating surface area.

G

H

5. Screw the new thermostatic

module (G) into the threaded port (H)
inside the trap body.

A

C

D

2a. Unscrew the thermostatic element (C) from

the cover (A).

b. Discard the old thermostatic element and

shroud (

, and washer (D).

C)

C)