beautypg.com

Bell & Gossett HS 218B Dura-Stat Thermostatic Module User Manual

Dura-stat, Thermostatic module, For barnes & jones thermostatic traps, model 122

background image

Xylem Inc.

8200 N. Austin Avenue

Morton Grove, Illinois 60053

Phone: (847) 966-3700

Fax: (847) 965-8379

www.xyleminc.com/brands/bellgossett

Bell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries.
© 2012 Xylem Inc. HS-218B October 2012 Part No. 510666

INSTRUCTION MANUAL

HS218B

Dura-Stat

Thermostatic Module

For Barnes & Jones

Thermostatic Traps,

Model 122,

1

/2”

CAUTION: TURN OFF STEAM SUPPLY

VALVE AND ALLOW RADIATOR

TO COOL BEFORE REPLACING

MODULE.

1 Remove the cover from the trap.

Then, remove the old thermostatic
element from the trap body. Discard the
old element.

IMPORTANT: After removing the old
element, be sure to remove any scale or
debris from the trap body interior,
especially in the area around the
machined seat.

2 Install the replacement Dura-Stat

Module in the Model 122 trap body by
inserting the module into the machined
seat. Then, place the retainer spring
included with the Dura-Stat Module on
top of the module as shown to the right.

3 Securely (leak tight) re-install the

cover on the trap body, taking care to
ensure that the retainer spring and
module remain squarely in the trap
body. Open the radiator supply valve.

COVER (SAVE)

OLD ELEMENT

(DISCARD)

1

2

3

NEW DURA-STAT

MODULE

RETAINER

SPRING

!