BELL & GOSSETT
PUMP
MODEL
NO.
SERIAL
NO.
IDENT.
NO.
G.P.M.
FT.
HP R.P.M.
P.S.I.
MAX.
WORK
PRESS.
6 x 8 x 12M
HSC3 12.4 LHR
1234567
K99
1250
125
60
1800
175
PUMP
SERIES
DUTY
POINT
MAXIMUM
WORKING PRESSURE
PUMP
SIZE
SERIAL
NUMBER
MONTH
AND YEAR
DRIVER
HP-60
IMPELLER DIAMETER
12.4"
LEFT HAND
ROTATION
OPERATIONAL LIMITS
Unless special provisions have been made for your pump by
Bell & Gossett, the operational limits for HSC
3
Series Pumps
are as follows:
175# Maximum Working Pressure
75# Maximum Suction Pressure
Listed on pump nameplate.
SEAL OPERATING LIMITS
Standard Self Flushing Mechanical Seals
BUNA-PH Limitations 7-9; Temperature Range -20 to +225°F
EPT-PH Limitations 7-11; Temperature Range -20 to +250°F
For use on closed or open systems which are relatively free of
dirt and/or other abrasive particles.
PUMP IDENTIFICATION
Bell & Gossett pumps are designated by a series of numbers
such as Series HSC
3
. The pump nameplate gives identification
and rating information as identified in Illustration 1.
Permanent records for this pump are kept by the serial number
and it must be used with all correspondence and spare parts
orders.
2
Illustration 1 – The Rating Plate
DESCRIPTION
The HSC
3
Series centrifugal pumps are frame mounted pumps
which feature – high efficiency, rugged construction, compact
design, foot mounted volute, center drop out coupler, and
regreasable bearings. These features, along with the horizontal
split case, make installation, operation, and service easy to
perform.
PUMP APPLICATION
The standard HSC
3
Series centrifugal pump’s bronze fitted
construction make it ideal for service with the following liquids:
unheated domestic and fresh water, boiler feed water, conden-
sate, hydronic cooling or heating, pressure boosting, general
pumping and benign liquids.