beautypg.com

Bell & Gossett A07211A Check-Trol Flange Operational Limits User Manual

Check-trol, Flange, Safety instruction

background image

Max Temperature

200°F (93°C)

Max Pressure

150psig (10 Bar)

INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER’S USE.

SAFETY INSTRUCTION

This safety alert symbol will be used in this manual to draw attention to safety related

instructions. When used, the safety alert symbol means ATTENTION! BECOME ALERT!

YOUR SAFETY IS INVOLVED! FAILURE TO FOLLOW THESE INSTRUCTIONS MAY

RESULT IN A SAFETY HAZARD.

DESCRIPTION

The Check-Trol™ Flange is a combination of an isolation valve, a spring check valve and

a  companion  flange  for  circulators.  The  Check-Trol™  flange  allows  easy  service  or

replacement of the circulator without the need to drain the system. The spring check

valve prevents system fluid from flowing in the wrong direction or unwanted direction.

The spring check valve also prevents gravity flow.

INSTALLATION INSTRUCTIONS

1. Install the Check-Trol™ Flange on the discharge side of the pump with arrow pointing

in the direction of flow (the Check-Trol™ Flange has “Check-Trol™” written on handle).

Install the Isolation Flange (without Check Valve) on the suction side of the pump.

2. See the following installation instructions and drawings for additional information.

3. Apply torque in even increments to both flange bolts. Refer to the pump manufac-

turers instruction manual for torque value. Both the suction and discharge flanges

must be torqued in this manner.

WARNING: System fluids under temperature or pressure can be hazardous.

Be  sure  the  pressure  is  relieved  and  system  temperature  is  below  100°F 

(38°C).  Failure  to  follow  these  instructions  could  result  in  property  damage  and/or

personal injury.

WARNING: To prevent leakage, make certain that the flange bolts have been

adequately  torqued.  Failure  to  follow  these  instructions  could  result  in

personal injury and/or property damage.

CAUTION: Over-tightening and breakage can occur with the use of teflon

pipe  joint  compounds.  Teflon  provides  lubricity  so  that  care  must  be

exercised not to over-tighten joints. Failure to follow these instructions could result in

property damage and/or personal injury.

www.bellgossett.com

For Check-Trol™ & Isolation Flange NPT Connections:

a) Apply pipe compound conservatively to the male connecting fittings only.

b) Upon completion of valves installation to piping, check connections for leaks.

Operational Limits

NOTE: This product is not intended for use in potable water applications.

NPT

CONNECTION

SWEAT

CONNECTION

BELL & GOSSETT

Check-Trol

 Flange

INSTRUCTION MANUAL

A07211 REVISION A

WARNING: California Proposition 65 Warning! This product contains chemicals known 

to the State of California to cause cancer and birth defects or other reproductive harm.