Bell & Gossett A07211A Check-Trol Flange Operational Limits User Manual
Check-trol, Flange, Safety instruction
![background image](/manuals/310225/1/background.png)
Max Temperature
200°F (93°C)
Max Pressure
150psig (10 Bar)
INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER’S USE.
SAFETY INSTRUCTION
This safety alert symbol will be used in this manual to draw attention to safety related
instructions. When used, the safety alert symbol means ATTENTION! BECOME ALERT!
YOUR SAFETY IS INVOLVED! FAILURE TO FOLLOW THESE INSTRUCTIONS MAY
RESULT IN A SAFETY HAZARD.
DESCRIPTION
The Check-Trol™ Flange is a combination of an isolation valve, a spring check valve and
a companion flange for circulators. The Check-Trol™ flange allows easy service or
replacement of the circulator without the need to drain the system. The spring check
valve prevents system fluid from flowing in the wrong direction or unwanted direction.
The spring check valve also prevents gravity flow.
INSTALLATION INSTRUCTIONS
1. Install the Check-Trol™ Flange on the discharge side of the pump with arrow pointing
in the direction of flow (the Check-Trol™ Flange has “Check-Trol™” written on handle).
Install the Isolation Flange (without Check Valve) on the suction side of the pump.
2. See the following installation instructions and drawings for additional information.
3. Apply torque in even increments to both flange bolts. Refer to the pump manufac-
turers instruction manual for torque value. Both the suction and discharge flanges
must be torqued in this manner.
WARNING: System fluids under temperature or pressure can be hazardous.
Be sure the pressure is relieved and system temperature is below 100°F
(38°C). Failure to follow these instructions could result in property damage and/or
personal injury.
WARNING: To prevent leakage, make certain that the flange bolts have been
adequately torqued. Failure to follow these instructions could result in
personal injury and/or property damage.
CAUTION: Over-tightening and breakage can occur with the use of teflon
pipe joint compounds. Teflon provides lubricity so that care must be
exercised not to over-tighten joints. Failure to follow these instructions could result in
property damage and/or personal injury.
www.bellgossett.com
For Check-Trol™ & Isolation Flange NPT Connections:
a) Apply pipe compound conservatively to the male connecting fittings only.
b) Upon completion of valves installation to piping, check connections for leaks.
Operational Limits
NOTE: This product is not intended for use in potable water applications.
NPT
CONNECTION
SWEAT
CONNECTION
BELL & GOSSETT
Check-Trol
™
Flange
INSTRUCTION MANUAL
A07211 REVISION A
WARNING: California Proposition 65 Warning! This product contains chemicals known
to the State of California to cause cancer and birth defects or other reproductive harm.