Pump station with ssh pumps – Xylem 10 001 247 R2 TechnoForce Package System User Manual
Page 31
Pump station with SSH pumps
Example product code
V
2
HE
F
4
P
A
L
2
BCD
Numbering system definitions
First character: Variable or constant speed
V = variable speed
C = constant speed
Second character: Number of pumps
2, 3, or 4
Third character: Pump type and size
H9 = 9SH
HA = 10SH
HB = 11SH
H4 = 4SH
H7 = 7SH
H5 = 5SH
H8 = 8SH
H6 = 6SH
HC = 24SH
HD = 25SH
HE = 22SH
HF = 27SH
HG = 23SH
HH = 28SH
—
—
Fourth character: Header size
C = 3 in.
E = 6 in.
G = 10 in.
D = 4 in.
F = 8 in.
H = 12 in.
Fifth character: Supply voltage
2 = 208 V / 1 PH / 60 Hz
6 = 460 V / 3 PH / 60 Hz
3 = 230 V / 1 PH / 60 Hz
7 = 575 V / 3 PH / 60 Hz
4 = 208 V / 3 PH / 60 Hz
8 = 380 V / 3 PH / 60 Hz
5 = 230 V / 3 PH / 60 Hz
9 = 380 V / 3 PH / 50 Hz
Sixth character: HP rating
A = 1/2
E = 2
J = 10
N = 30
T = 75
B = 3/4
F = 3
K = 15
P = 40
U = 100
C = 1
G = 5
L = 20
R = 50
V = 125
D = 1-1/2
H = 7-1/2
M = 25
S = 50
W = 150
Seventh character: Trim
9SH
10SH
11SH
4SH
7SH
5SH
8SH
6SH
22SH
23SH
24SH
25SH
27SH
28SH
A
6-5/8
8-27/6
4
10-3/3
2
6-3/4
8-1/4
6-7/8
8-1/4
7-5/16 9-1/16 9-1/16 9-7/8
9-7/8
10-3/8 10-5/8
B 6-7/16 8-1/16 9-17/3
2
6-3/8
7-13/16 6-7/16 7-3/4
7-1/8
8-3/4
8-11/1
6
9-1/2
9-1/2
9-15/1
6
10-1/4
C
5-11/16 7-11/1
6
9-1/8
6-1/16 7
5-13/1
6
7-1/2
6-15/1
6
8-1/2
8-6/16 9-3/16 9-1/8
9-9/16 9-13/16
D 5-3/8
7-3/8
8-3/4
5-5/8
6-3/4
5-1/2
7-3/16 6-11/1
6
8-1/4
8-1/16 8-7/8
8-13/16 9-1/4
9-7/16
E
—
7-1/8
—
5-5/16 6-7/16 5-1/8
6-7/8
6-3/8
7-7/8
7-11/1
6
8-9/16 8-3/16 8-3/4
9-1/16
Technical Reference
TechnoForce Package System Mechanical Installation, Operation, and Maintenance Manual
29