Diodes 74LVC1G34 User Manual
Page 4

74LVC1G34
Document number: DS36108 Rev. 3 - 2
4 of 15
March 2014
© Diodes Incorporated
NEW PROD
UC
T
74LVC1G34
Recommended Operating Conditions
(Note 8)
Symbol Parameter
Min
Max
Unit
V
CC
Operating Voltage
Operating 1.65
5.5
V
Data Retention Only
1.5
—
V
V
IH
High-Level Input Voltage
V
CC
= 1.65V to 1.95V
0.65 X V
CC
—
V
V
CC
= 2.3V to 2.7V
1.7
—
V
CC
= 3V to 3.6V
2
—
V
CC
= 4.5V to 5.5V
0.7 X V
CC
—
V
IL
Low-Level Input Voltage
V
CC
= 1.65V to 1.95V
—
0.35 X V
CC
V
V
CC
= 2.3V to 2.7V
—
0.7
V
CC
= 3V to 3.6V
—
0.8
V
CC
= 4.5V to 5.5V
—
0.3 X V
CC
V
I
Input Voltage
0 5.5 V
V
O
Output Voltage
0
V
CC
V
I
OH
High-Level Output Current
V
CC
= 1.65V
—
-4
mA
V
CC
= 2.3V
—
-8
V
CC
= 2.7V
—
-12
V
CC
= 3V
— -16
— -24
V
CC
= 4.5V
—
-32
I
OL
Low-Level Output Current
V
CC
= 1.65V
—
4
mA
V
CC
= 2.3V
—
8
V
CC
= 2.7V
—
-12
V
CC
= 3V
— 16
— 24
V
CC
= 4.5V
—
32
∆t/∆V
Input Transition Rise or Fall Rate
V
CC
= 1.8V ± 0.15V, 2.5V ± 0.2V
—
20
ns/V
V
CC
= 3.3V ± 0.3V
—
10
V
CC
= 5V ± 0.5V
—
5
T
A
Operating Free-Air Temperature
-40
+125
°C
Note:
8. Unused inputs should be held at V
CC
or Ground.