Ah276q, Recommended operating conditions, Electrical characteristics – Diodes AH276Q User Manual
Page 3: Magnetic characteristics, O u tput volta g e ) b, 0s n ( magnetic flux density b ) do, 0s n ( magnetic flux density b ) dob

AH276Q
Document number: DS31066 Rev. 6 - 2
3 of 6
September 2013
© Diodes Incorporated
AH276Q
Recommended Operating Conditions
(@T
A
= +25°C, unless otherwise specified.)
Symbol
Parameter
Conditions
Min
Max
Unit
V
CC
Supply Voltage (Note 4)
Operating
3.5
20
V
T
A
Operating Ambient Temperature
Operating
-20
+85
C
Note: 4. The output DO/DOB is switching as magnetic field change (S>300G, N<-300G).
Electrical Characteristics
(@T
A
= +25°C, unless otherwise specified.)
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
V
Z
Output Zener Breakdown
—
35
—
V
V
CE(SAT)
Output Saturation Voltage
V
CC
= 14V, I
L
= 400mA
—
0.6
0.9
V
I
CEX
Output Leakage Current
V
CE
= 14V, V
CC
= 14V
—
<0.1
10
µA
I
CC
Supply Current
V
CC
= 20V, Output Open
7
16
25
mA
Magnetic Characteristics
(Note 5) (@T
A
= +25°C, V
CC
= 14V, unless otherwise specified.)
A grade
Symbol
Characteristic
Min
Typ
Max
Unit
Bop
Operate Point
10
—
50
Gauss
Brp
Release Point
-50
—
-10
Gauss
Bhy
Hysteresis
—
75
—
Gauss
B grade
Symbol
Characteristic
Min
Typ
Max
Unit
Bop
Operate Point
5
—
70
Gauss
Brp
Release Point
-70
—
-5
Gauss
Bhy
Hysteresis
—
75
—
Gauss
C grade
Symbol
Characteristic
Min
Typ
Max
Unit
Bop
Operate Point
—
—
100
Gauss
Brp
Release Point
-100
—
—
Gauss
Bhy
Hysteresis
—
75
—
Gauss
Note: 5. Magnetic characteristics are for design information, which will vary with supply voltage, operating temperature and after soldering.
B
hy
V
sat
V
cc
(
O
u
tput Volta
g
e )
B
rp
B
op
0
S
N
( Magnetic flux density B )
DO
Turn on
Turn off
( off-state )
( on-state )
B
hy
V
sat
V
cc
(
O
u
tput Volta
g
e )
B
rp
B
op
0
S
N
( Magnetic flux density B )
DOB
Turn oFF
Turn on
( off-state )
( on-state )