TLV431
Document number: DS32088 Rev. 6 - 2
2 of 14
October 2012
© Diodes Incorporated
TLV431
A Product Line of
Diodes Incorporated
Absolute Maximum Ratings
(@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter
Rating
Unit
V
KA
Cathode Voltage
20
V
I
KA
Continuous Cathode Current
-20 to +20
mA
I
REF
Reference Input Current Range
-0.05 to +3
mA
V
IN
Input Supply Voltage (Relative to Ground)
-0.03 to +18
V
ESD Susceptibility
HBM
Human Body Model
4
kV
MM Machine
Model
400
V
CDM Charged
Device
Model
1
kV
(Semiconductor devices are ESD sensitive and may be damaged by exposure to ESD events. Suitable ESD precautions should be taken when handling and
transporting these devices.)
Parameter Rating
Unit
Operating Junction Temperature
-40 to +150
°C
Storage Temperature
-65 to +150
°C
Operation above the absolute maximum rating may cause device failure.
Operation at the absolute maximum ratings, for extended periods, may reduce device reliability.
Unless otherwise stated voltages specified are relative to the ANODE pin.
These are stress ratings only. Operation outside the absolute maximum ratings may cause device failure.
Recommended Operating Conditions
(@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter Min
Max
Units
V
KA
Cathode Voltage
V
REF
18 V
I
KA
Cathode Current
0.1
15
mA
T
A
Operating Ambient Temperature Range
-40 +125 °C
Package Thermal Data
Package
θ
JA
P
DIS
T
A
= +25°C, T
J
= +150°C
SOT23 380°C/W
330mW
SOT25 250°C/W
500mW
SC70-6
(SOT363)
380°C/W 330mW