2. Scenario #2: If some of the drives in a configuration are removed

and re-inserted, the controller considers the drives to have foreign

configurations.

Import or clear the foreign configuration. If you select Import, automatic

rebuilds will occur in redundant virtual drives.

Start a consistency check immediately after the rebuild is complete to ensure

data integrity for the virtual drives.

3. Scenario #3: If all the drives in a virtual drive are removed, but at

different times, and re-inserted, the controller considers the drives to

have foreign configurations.

Import or clear the foreign configuration. If you select Import, all drives

that were pulled before the virtual drive became offline will be imported

and then automatically rebuilt. Automatic rebuilds will occur in redundant

virtual drives.

4. Scenario #4: If the drives in a non-redundant virtual drive are removed,

the controller considers the drives to have foreign configurations.

Import or clear the foreign configuration. No rebuilds will occur after

the import operation because there is no redundant data to rebuild the

drives with.