beautypg.com

Chapter 6 – Asus TS700-E7/RS8 User Manual

Page 139

background image

TS700-E7/RS8

6-19

Chapter 6

3. When prompted, use the arrow keys to select Yes from the Consistency

Check? dialog box, and then press .

A progress bar appears on screen.

4. While checking the disk consistency, press to display the following

options.

• Stop

- Stops the consistency check. The utility stores the percentage of

disk checked, and when you restart checking, it continues from

the last percentage completed rather than from zero percent.

• Continue - Continues the consistency check.

• Abort - Aborts the consistency check. When you restart checking, it

continues from zero percent.

5. When checking is complete, press any key to continue.

Management Menu

Configure

Initialize

Objects

Rebuild

Check Consistency

Virtual Drive(s) Configured

LD RAID Size #Stripes StripSz Status

0 10 154494MB 4 64 KB ONLINE

Consistency Check?

Yes

No

Select VD

LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010

BIOS Version A.10.09231523R

SPACE-(De)Select, F10-Check Consistency

Management Menu

Configure

Initialize

Objects

Rebuild

Check Consistency

Virtual Drive(s) Configured

LD RAID Size #Stripes StripSz Status

0 10 154494MB 4 64 KB ONLINE

Virtual

Virtual Drive 0

CC Under Process

VD 0 Consistency Check. Press Esc to Abort.

¦ 85 % Completed

The Data On The Drives Is Inconsistency. Repair

Done!

LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010

BIOS Version A.10.09231523R

SPACE-(De)Select, F10-Check Consistency

Virtual Drives

Virtual Drive 0