5 rebuilding the raid, 4 exiting the intel – Asus RS740-E7-RS24-EG User Manual
Page 163
ASUS RS740-E7-RS24-EG
6-29
Select a destination disk with the same size as the original hard disk.
6.3.5
Rebuilding the RAID
This option is only for the RAID 1 set.
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID 1 array failed, the system displays
the status of the RAID volume as “Degraded” during POST. You can rebuild the RAID array
with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1.
During POST, press
Technology option ROM utility.
2.
If there is a non-RAID SATA Hard Disk available, the utility will prompt you to rebuild the
RAID. Press the up/down arrow keys to select the destination disk then Press
to start the rebuilding process, or press
6.3.4
Exiting the Intel
®
Rapid Storage Technology enterprise
SATA Option ROM utility
To exit the utility:
1.
From the utility main menu, select 4. Exit then press
2.
Press
Select the port of destination disk for rebuilding (ESC to exit):
Port Drive Model Serial # Size
X XXXXXXXXXXX XXXXXXXX XXX.GB
“Degraded” volume and disk available for rebuilding detected. Selectign
a disk initiates a rebuild. Rebuild completes in the operating system.
[ ]-Previous/Next [ENTER]-Select [ESC]-Exit
[
DEGRADED VOLUME DETECTED
]
Are you sure you want to exit? (Y/N):
[
CONFIRM EXIT
]