CDT900 Series Touchscreen Programmable Thermostata
Table 3.installer Setup Menu. (CONTINUES)
Installer Setup
Number
Installer Setup
Name
Settings Notes
0360
Heat Pump Auxiliary
Lockout
0-no auxiliary heat lockout.
40°F (4.5°C)
45°F (7°C)
50°F (10°C)
55°F (13°C)
60°F (15.5°C)
Shown if electric is chosen for
backup heat source and
outdoor temperature sensor
for control is selected. (See
Advanced Features section for
more information.)
0380
Indoor
Dehumidification
Control
0-No indoor dehumidification control.
1-Dehumidification control activated.
Available on select odels. If
dehumidification control is
activated and auto-
changeover is selected in
Installer Setup Number 0300,
the deadband minimum is
defaulted to 5°F (3°C) in
Number 0310.
0500
Furnace Change
Reminder
0-furnace filter reminder off
1-10 run time days
2-30 run time days
3-60 run time days
4-90 run time days
5-120 run time days
6-365 run time days
Run time based on call for fan.