CDT900 Series Touchscreen Programmable Thermostata
Table 3.installer Setup Menu. (CONTINUES)
Installer Setup
Number
Installer Setup
Name
Settings Notes
0330 Daylight
Savings
1-daylight savings is on (factory setting).
0-daylight savings is off.
Set to 0 in areas that do not
follow daylight savings.
0340
Remote Temperature
Sensor (Outdoor or
Indoor)
0-no remote temperature sensor
1-outdoor temperature sensor for display
only.
2-outdoor temperature sensor for
control.Outdoor sensor used for Heat Pump
Lockout settings. (See Heat Pump
Temperature Lockout section for more
details.)
3-indoor temperature sensor
Defaults and Options depend
on System Type selection.
Indoor Temperature Sensor
uses an averaging network
and does not include on-board
sensor.
0350
Heat Pump
Compressor Lockout
or (Balance Point)
0-no compressor lockout.
15°F (-9.5°C)
20°F (-6.5°C)
25°F (-4°C)
30°F (-1°C)
35°F (1.5°C)
40°F (4.5°C)
45°F (7°C)
Default depends on other
selections. Shown if control is
selected. (See section for
more information.)