Q-Tech QT822 Square Wave User Manual
Page 8
QT821 and QT822 Square-Wave
32 PIN Flat-Pack
REV.
Q-TECH Corporation
10150 W. Jefferson Blvd.
Culver City, CA 90232
SIZE
A
CAGE NO.
51774
Sheet 8 of 10
E
3.5 Traceability Requirements
Material, element and process traceability requirements shall be as specified by MIL-PRF-38534 for
Class K hybrids.
3.6 Data
3.6.1. Design Documentation - When required by the purchase order, design, topography, process and
flow charts for all assembly/inspection and test operation for devices to be supplied under this
specification on the initial procurement shall be established and shall be available in-plant for
review by the procuring activity upon request. This design documentation shall be sufficient to
depict the physical and electrical construction of the devices supplied under the specification and
shall be traceable to the specific parts, drawings or part type numbers to which it applies, and to
the production lot(s) and inspection lot codes under which devices are manufactured and tested so
that revisions can be identified.
3.6.2. Technical Data Package. When required by the purchase order, the following design
documentation and information is deliverable 30 days prior to the start of production. The
Technical Data Package shall consist of the following:
a) Assembly drawing(s).
b) All electrical schematics and drawings not considered proprietary.
c) The assembly and screening travelers to be used on-line to manufacture the devices
supplied to this specification.
d) Parts and materials list.
3.7
Test Report
A test report is supplied with each shipment of oscillators and includes the following information, as
a minimum:
a) A Certificate of Conformance to all specifications and purchase order requirements. As a
minimum, the Certificate of Conformance shall include the following information:
Purchase order number
Applicable part number
Manufacturer’s lot number
Lot date code
b) Parts and materials traceability information.
c) Certificate of crystal sweeping.
d) Manufacturing lot traveler.
e) Screening attributes and variables data as applicable.
f) Quality conformance inspection attributes and variables data as applicable.
g) Radiographic inspection negatives.
ITAR-CONTROLLED Q-TECH PROPRIETARY DO NOT COPY OR DISTRIBUTE WITHOUT Q-TECH APPROVAL