beautypg.com

Q-Tech QT6T User Manual

Page 4

background image

MIL-PRF-55310/16J

4

TABLE I. Dash numbers and operating characteristics.

Dash
number

Pulse characteristics

Frequency-temperature

tolerance (ppm)

Package

(Max

height)

-55°C

to

+125°C

-55°C

to

+105°C

-20°C

to

+70°C

A B

Output
frequency
range

Input

current

max at

5.25 V

±1%

1/

Rise

and

fall

times

max

Duty

cycle

at

1.4 V

Load

max

2/

Initial

accuracy

ppm

at

+23°C

±1°C

Frequency

aging

ppm/year

after

30 days

A B C

01

02


0.1 Hz to
250 Hz

mA

158

ns
15

percent

45 to

55

10

TTL

±15

±5

±50

±40

±25

04

05

0.1 Hz to
250 Hz

158

15

45 to

55

10

TTL

±25

±10

±100

±80

±50

11

12

250 Hz to
150 kHz

94

15

45 to

55

10

TTL

±15

±5

±50

±40

±25

14

15

250 Hz to
150 kHz

94

15

45 to

55

10

TTL

±25

±10

±100

±80

±50

21

22

150 kHz
to 5 MHz

70

15

45 to

55

10

TTL

±15

±5

±50

±40

±25

24

25

150 kHz
to 5 MHz

70

15

45 to

55

10

TTL

±25

±10

±100

±80

±50

31

32

4 MHz to
20 MHz

30

15

40 to

60

10

TTL

±15

±5

±50

±40

±25

34

35

4 MHz to
20 MHz

30

15

40 to

60

10

TTL

±25

±10

±100

±80

±50

41

42

20 MHz to
80 MHz

65

5

40 to

60

6

TTL

±15

±5

±50

±40

±25

44

45

20 MHz to
80 MHz

65

5

40 to

60

6

TTL

±25

±10

±100

±80

±50

1/ Maximum input current for no load condition. Actual configuration of TTL loads must be added to

determine power supply requirements.

2/ A TTL unit load is defined as: 1.6 mA sink, 0.04 mA source, and 2 pF capacitance.

Frequency-voltage tolerance:

±2 ppm maximum for a ±10 percent change in supply voltage. Measurements taken

at reference temperature and operating temperature range end points.

Frequency aging: Measurements shall be taken at +70

°C ±0.2°C at intervals of not more than every 72 hours for

30 days minimum (see table I).

±5 ppm per year, maximum

±10 ppm per year, maximum


±0.7 ppm per 30 days.

±1.5 ppm per 30 days

±1.5 ppm per 90 days

±3 ppm per 90 days


Terminal strength: Method 211 of MIL-STD-202, test condition C.

Applied force: 2 pounds each terminal for 10 seconds.

Bends: Five at 45 degrees each.

Frequency-environmental tolerance: Not applicable.

Vibration, sinusoidal: In accordance with

MIL-PRF-55310

and

method 204 of MIL-STD-202

.


Nonoperating: Test condition D.

Operating: Not required.