Q-Tech QT66HCD User Manual
Page 4

MIL-PRF-55310/29C
4
TABLE I. Dash numbers and operating characteristics.
1/ Maximum input current for no load condition.
2/ Up to 30 days following shipment.
3/ After 30 days following shipment.
4/ See figure 3.
TABLE II. Frequency aging limits.
1/ See table I.
Initial frequency - temperature accuracy (1/2 temperature cycle): See table I. Measurements shall be taken at ten
equally spaced increments over the specified operating temperature range.
Frequency - voltage tolerance for
±10 percent change in supply voltage:
For output frequency
≤ 40.0 MHz: ±2 ppm, maximum.
For output frequency
≥ 40.0 MHz: ±4 ppm, maximum.
Frequency - environmental tolerance:
±3 ppm.
Frequency aging: Frequency aging shall be in accordance with
MIL-PRF-55310
and shall meet the limits of
table II.
Dash
number
Output
frequency
Input
current
Pulse characteristics
Initial
accuracy
Frequency
aging
Frequency-temperature
tolerance (ppm)
range
(max)
1/
Rise and
fall times
(max)
Duty Cycle
min-max
4/
at +23
°C
±1°C
2/
ppm/year
(max) 3/
-55/C
to
+125/C
-55/C
to
+105/C
-20/C
to
+70/C
A
B
C
01
to
02
0.2 MHz
5.0 MHz
10 mA
10 mA
10 ns
10 ns
45% to 55%
±15 ppm
±25 ppm
±5 ppm
±10 ppm
±65 ppm
±100 ppm
±55 ppm
±75 ppm
±40 ppm
±50 ppm
11
to
12
5.0 MHz
25.0 MHz
20 mA
20 mA
10 ns
10 ns
45% to 55%
±15 ppm
±25 ppm
±5 ppm
±10 ppm
±65 ppm
±100 ppm
±55 ppm
±75 ppm
±40 ppm
±50 ppm
21
to
22
25.0 MHz
40.0 MHz
30 mA
30 mA
5 ns
5 ns
45% to 55%
±15 ppm
±25 ppm
±5 ppm
±10 ppm
±65 ppm
±100 ppm
±55 ppm
±75 ppm
±40 ppm
±50 ppm
31
to
32
40.0 MHz
60.0 MHz
40 mA
40 mA
5 ns
5 ns
40% to 60%
±15 ppm
±25 ppm
±5 ppm
±10 ppm
±65 ppm
±100 ppm
±55 ppm
±75 ppm
±40 ppm
±50 ppm
41
to
42
60.0 MHz
85.0 MHz
60 mA
60 mA
5 ns
5 ns
40% to 60%
±15 ppm
±25 ppm
±5 ppm
±10 ppm
±65 ppm
±100 ppm
±55 ppm
±75 ppm
±40 ppm
±50 ppm
±5 ppm per year 1/
±10 ppm per year 1/
Maximum change over 30 days
±0.7 ppm
±1.5 ppm
Projected maximum change
for 1 year after 30 days
±5.0 ppm
±10.0 ppm