MIL-PRF-55310/34C
5
Frequency aging: Measurements shall be taken at +70°C ±0.2°C at intervals of not more than every 72 hours for
30 days minimum (Except one maximum interval of 96 hours per 30 days is permitted).
±
10 ppm per year, maximum
±
1.5 ppm per 30 days.
±
3 ppm per 90 days.
Terminal strength:
Method 211 of MIL-STD-202
, test condition A.
Applied force: 8 ounces each terminal.
Frequency-environmental tolerance: Not applicable.
NOTES:
1. For C
CL
= 15 pF ±5 percent.
2. For R
CL
= 10 kΩ ±5 percent.
3. C
CL
includes scope capacitance.
FIGURE 2. Load test circuit.
See also other documents in the category Q-Tech Accessories for electrical:
- QT606L (5 pages)
- QT6T w__Gate (5 pages)
- QT812 Square Wave (10 pages)
- QT6C (6 pages)
- QT93 (5 pages)
- SINE WAVE (6 pages)
- QT488 (7 pages)
- QT92ND (6 pages)
- QT28 (6 pages)
- QT88HCD (7 pages)
- QT78 (6 pages)
- QT88RD (6 pages)
- CLASS B+ (27 pages)
- QT62T (4 pages)
- QT806 Sine Wave (10 pages)
- QT78HCD (6 pages)
- QT802 Square Wave (10 pages)
- QT83 (6 pages)
- QT75 (7 pages)
- QT3 (6 pages)
- QT89 (6 pages)
- QT4T (5 pages)
- QT84 (6 pages)
- QT641L (5 pages)
- QT1C (4 pages)
- QTV716 Sine Wave (7 pages)
- QT92RD (6 pages)
- QT66T (5 pages)
- QCC325 (4 pages)
- QCC570 (4 pages)
- QT66HCD (7 pages)
- QT10C (5 pages)
- QT39E (9 pages)
- QT606C (6 pages)
- QT641C (5 pages)
- QT625C (6 pages)
- QT10T (5 pages)
- QTV722 Square Wave (8 pages)
- QT816 Sine Wave (10 pages)
- QCC570LW (4 pages)
- QT3T (4 pages)
- QT3C (4 pages)
- QTV726 Sine Wave (7 pages)
- QT88 (6 pages)