beautypg.com

Q-Tech QT6T w__Gate User Manual

Page 4

background image

MIL-PRF-55310/17F

4

TABLE I. Dash numbers and operating characteristics.

1/ Maximum input current for no load condition. Actual configuration of TTL loads must be added to determine

power supply requirements.

2/ A TTL unit load is defined as: 1.6 mA sink, 0.04 mA source, and 2 pF capacitance.


Frequency-temperature tolerance (one-half temperature cycle, referenced to frequency measured at +23

C 1C,

immediately prior to starting of the test): See table I. Measurements taken at ten equally spaced increments
over the specified operating temperature range. 1/

Frequency-voltage tolerance:

2 ppm maximum for a 10 percent change in supply voltage. Measurements taken

at reference temperature and operating temperature range end points.

Frequency aging: Measurements shall be taken at +70

C 0.2C at intervals of not more than every 72 hours for

30 days minimum (see table I).

5 ppm per year, maximum

10 ppm per year, maximum

0.7 ppm per 30 days.

1.5 ppm per 30 days

1.5 ppm per 90 days

3 ppm per 90 days


Terminal strength:

Method 211 of MIL-STD-202

, test condition C.


Applied force: 2 pounds each terminal for 10 seconds.

Bends: Five at 45 degrees each.

Frequency-environmental tolerance: Not applicable.

1/ For the purpose of transitioning this device to

MIL-PRF-55310

, ‘Frequency stability versus temperature’ has

been renamed ‘Frequency-temperature tolerance’. The verification requirements of ‘initial frequency-

temperature accuracy (one-half temperature cycle)’ shall apply except that frequency measurements shall

be referenced to the frequency measured at +23

C 1C (f

ref

) instead of to the nominal frequency (f

nom

).






Dash
num-
ber

Output

frequency

range

Input

current

max at

5.25 V

1%

1/

Pulse characteristics

Initial

accuracy

ppm

at

+23

C

1C

Frequency

aging

ppm/year

after

30 days

Frequency-temperature

tolerance (ppm)

Rise

and

fall

times

max

Duty

cycle at

1.4 V

Load

max

2/

-55

C

to

+125

C

-55

C

to

+105

C

-20

C

to

+70

C

A

B

C

percent

01

250 kHz to
5 MHz

65 mA

15 ns

45 to 55

10 TTL

15 ppm

5 ppm

50

ppm

40
ppm

25
ppm

04

250 kHz to
5 MHz

65 mA

15 ns

45 to 55

10 TTL

25 ppm

10 ppm

100

ppm

40
ppm

25
ppm

11

4 MHz to
20 MHz

55 mA

15 ns

40 to 60

10 TTL

15 ppm

5 ppm

50

ppm

40
ppm

25
ppm

14

4 MHz to
20 MHz

55 mA

15 ns

40 to 60

10 TTL

25 ppm

10 ppm

100

ppm

40
ppm

25
ppm

21

20 MHz to
50 MHz

55 mA

5 ns

40 to 60

10 TTL

15 ppm

5 ppm

50

ppm

40
ppm

25
ppm

24

20 MHz to
50 MHz

55 mA

5 ns

40 to 60

10 TTL

25 ppm

10 ppm

100

ppm

40
ppm

25
ppm