Section 6: SPECIFICATION AND OPERATING DATA

ITEM

APIF100

APIF100DM

APIF100J

APIF100M

APIF100MDM

APIF100PT

APIF100PTDM

APIF100MPT

APIF100MPTDM

APIF100MJ

APIF150

APIF150DM

APIF150J

APIF150M

APIF150MDM

APIF150PT

APIF150PTDM

APIF150MPT

APIF150MPTDM

APIF150MJ

APIF200

APIF200DM

APIF200J

APIF200M

APIF200MDM

APIF200PT

APIF200PTDM

APIF200MPT

APIF200MPTDM

APIF200MJ

APIF300

APIF300J

APIF300M

APIF300PT

APIF300MPT

APIF300MJ

Media Volume, cu. ft. (cu. mtr.) (Note 1):
Gravel Underbed, lbs. (kg)
Nominal Capacity, ppm-gal.

Operating Service Flow Rate, gpm (lpm) (Note 2):

Pressure Loss @ Service Flow Rate, psi (kPa)

Backwash Flow Rate, gpm (lpm) Note 3

Service Pipe Size, in. (cm) (Note 4)

Media tank Diameter x Height, in. (cm)

Minimum Space Required, in. (cm):
Width
Depth (w/Bypass)
Height

Approximate Shipping Weight, lbs. (kg)

1.0 (0.03)

13 (5.9)

30,000

6 (22.7)

5 (34.5)

5.3 (20.1)

1 (2.5)

10 x 44

(26 x 112)

12 (30)
16 (41)

53 (135)

143 (64.9)

1.5 (0.04)

13 (5.9)

45,000

7 (26.5)

7 (48.2)

5.3 (20.1)

1 (2.5)

10 x 54

(26 x 137)

12 (30)
16 (41)

63 (160)

186 (84.4)

2.0 (0.06)

18 (8.2)

60,000

9 (34.1)

8 (55.1)

7.5 (28.4)

1 (2.5)

12 x 54

(30 x 137)

12 (30)
16 (41)

63 (160)

257 (116.6)

3.0 (0.08)

26 (11.8)

90,000

12 (45.4)

10 (68.9)

10 (37.9)

1 (2.5)

14 x 65

(36 x 165)

13 (33)
16 (41)

74 (188)

353 (160.2)

Maximum Operating Temperature 110°F (43.3°C); Electrical requirements 110V/60Hz; Operating Pressure 20 -125 psi (138-861
kPa). Specifi cations subject to change without notice.

6-2

IMPORTANT NOTE

1) Replenishment of pH adjusting component of media may be required periodically, the frequency of which is dependent on raw water pH,

manganese concentration and water consumption rate. Consult dealer for more information.

2) For satisfactory performance, indicated durations should not be exceeded. Flow rates specifi ed are adequate for normal residential applica-

tions. Do not use Service or Peak fl ow rates when sizing commercial applications or if treated water is to supply a geothermal heat pump,
swimming pool, etc. (contact dealer before selecting equipment). Service fl ow rates have been tested against NSF Standard 42 and have a
rated pressure drop of less than 10 psi.

3) For system to operate properly, pumping rate of well pump MUST be suffi cient to backwash unit at rate specifi ed.