Section 6: VALVE SPECIFICATION AND OPERATING DATA

Maximum Service Flow Rate:
Includes Bypass Valve

27 gpm (102.2 lpm) @ 15 psig (103 kPa) drop

Maximum Backwash Flow Rate:
Includes Bypass Valve

27 gpm (102.2 lpm) @ 15 psig (103 kPa) drop

Minimum/Maximum Operating Pressure:

20 psi (138 kPa) - 125 psi (862 kPa)

Minimum/Maximum Operating Temperature:

40°F (4.4°C) - 110°F (43.3° C)

AC Adapter:
Supply Voltage
Supply Frequency
Output Voltage
Output Current

U.S.

120 V. AC

60 Hz

12 V. AC

500 mA

Drain Line Flow Control

Unit Size

Number on

Drain Line

Flow Control

Backwash Flow

Rate (gpm)

Backwash Flow

Rate (lpm)

1.0 ft

3

053

5.3

20.1

1.5 ft

3

053

5.3

20.1

2.0 ft

3

075

7.5

28.4

3.0 ft

3

100

10.0

37.9

Inlet/Outlet Tube Opening

(a) 1” Universal Elbow
(b) 1” Straight brass sweat fi tting
(c) 1” Plastic male NPT fi tting

Distributor Tube Opening

1.05” OD (3/4 NPS)

Tank Thread

2 1/2”- 8 NPSM to Flanged Adapter

Control Valve Weight

4.5 lbs. (2.0 kg)

PC Board Memory

Nonvolatile EEPROM
(electronic erasable programmable read only memory)

6-1

Note: After completing any valve maintenance involving the drive assembly or the drive cap assembly and pistons, unplug the power source from the
jack on the printed circuit board (black wire) and plug back in. This resets the electronics and establishes the service piston position.