Caution, Gravel and chem-free media schedule – Aqua-Pure APIF100 User Manual
Page 10
3-2
GRAVEL AND CHEM-FREE MEDIA SCHEDULE
Unit Model Number
APIF100 Models
(APIF100, APIF100DM, APIF100J, APIF100M,
APIF100MDM, APIF100PT, APIF100PTDM,
APIF100MPT, APIF100MPTDM,APIF100MJ)
APIF150 Models
(APIF150, APIF150DM, APIF150J, APIF150M,
APIF150MDM, APIF150PT, APIF150PTDM,
APIF150MPT, APIF150MPTDM, APIF150MJ)
APIF200 Models
(APIF200, APIF200DM, APIF200J, APIF200M,
APIF200DM, APIF200PT, APIF200PTDM,
APIF200MPT, APIF200MPTDM, APIF200MJ)
APIF300 Models
(APIF300, APIF300J, APIF300M,
APIF300PT, APIF300MPT, APIF300MJ)
Filter Media
MC-10P
MC-10P
MC-050P
MC-10P (2)
MC-10P (3)
NOTE: If you ordered an “M” model iron and manganese reduction system, the fi lter pack media would be designated by an M at the end of the part
number i.e. MC-10MP.
To load the fi lter media into the media tank please use the follow steps. This is necessary to ensure that the distributor tube has not been pulled up when
the control valve was removed from the top of the media tank.
Step 1
a) Remove from the shipping carton the fi lter unit
b) Carefully remove the control valve from the tank by rotating the valve head assembly to the left (counter-clockwise).
c) Set all items aside for future use. Ensure that the following items have been shipped entirely with the unit to allow for proper and complete installation. I
i. Control
valve
ii.
Media tank (also a reducing bushing and fl anged adapter on APIF300)
iii. Bypass
valve
iv.
1” Male NPT Connection Kit
v.
Media (amount will vary by fi lter size)
vi. Distributor
Tube
vii.
Drain line assembly kit
viii. Parts
bag
ix. Hydrocharger
x.
Installation and Operating Instructions
xi. Loading
funnel
xii. Centering
Tool
d) Remove the distributor tube in the tank, set aside and pour the gravel into a clean pail for later use.
e) Reinsert the distributor tube into the tank and ensure the tube is centered in the tank; a dimple is in the center of the tank to help in doing so. Using the
centering tool and cap, cover the distributor tube opening to prevent fi lter media and gravel from entering the distributor tube during the loading of the tank.
f) Threaded Tank Models: APIF100, APIF100J, APIF100PT, APIF100MPT, APIF100MJ, APIF150, APIF150J, APIF150M, APIF150PT, APIF150MPT, APIF150MJ,
APIF200, APIF200J, APIF200PT, APIF200MPT, APIF200MJ, APIF300, APIF300J, APIF300PT, APIF300MPT, APIF300MJ: Place the funnel provided, in the opening
of the media tank to aid in loading the gravel and fi lter media. Pour the QC gravel into the tank slowly. While holding the distributor tube in place, shake the
tank from side to side gently, to aid in leveling the QC gravel. Do not allow gravel to get under the basket of the distributor tube during the loading of gravel.
If this happens, pour out the gravel and remove the distributor tube once again and reload gravel once again. Next locate the fi lter media and slowly pour
into the tank. Again shake the tank from side to side to aid in leveling the media. Next, using a hose or clean pail, fi ll the tank with water to saturate the fi lter
media and expel any air that may be present, remove the extension tube, cap and funnel, and save for future servicing.
g) Dome Hold Tank Models: APIF100DM, APIF100PTDM, APIF100MDM, APIF100MPTDM, APIF150DM, APIF150PTDM, APIF150MDM, APIF150MPTDM, APIF200DM,
APIF200PTDM, APIF200MDM, APIF200MPTDM:
Add media through fi llport cap located on tank using funnel (See FILLING MEDIA TANK below). Fillport cap can be removed by turning a quarter turn counter clockwise.
CAUTION
CAUTION
To reduce the risk associated with skin, eye, and respiratory tract irritation from dust
from fi lter media during installation:
• Gravel and several types of fi lter media may be used in this product, depending upon the
application. During installation, dust may cause irritation to skin, eyes, and respiratory
tract, and may affect lungs.
• Utilize a NIOSH-approved dust fi lter mask and appropriate eye protection when handling
and pouring gravel and fi lter media.
• To request an MSDS relating to this product, call 203-238-8965 or go to www.3M.com ,
select country, and use the search engine to search MSDS. For emergencies, call 800-
364-3577 or 651-737-6501 (24 hours).
Reinstall fi llport cap by turning a quarter turn clockwise.
If bypass valve assembly is not factory pre-installed, attach using clips and screws.
Using a clean dry rag, wipe the opening of the media tank to remove any dust or residue from the opening to receive the control valve. Attach the valve head
to the media tank by rotating the valve head assembly to the right (clockwise).
Step 2
Shut off water at main supply. On a PRIVATE WELL SYSTEM turn off the power to the WELL PUMP and drain PRESSURE TANK. Make certain all water pressure
has been relieved from water system by opening nearest faucet to drain water system. SHUT OFF FUEL SUPPLY TO WATER HEATER OR BOILER.
FILLING MEDIA TANK