Caution, Figure 1, Variable speed / constant pressure pump install – Aqua-Pure CSX200 User Manual
Page 8: Split-stream installation
SECTION 3: INSTALLATION
Proper installation sequence of water conditioning equipment is very important. Refer to the following diagram for your particular water supply.
3-1
CAUTION
To reduce the risk associated with property damage due to plugged water lines:
• Pay particular attention to correct orientation of control valve. Water fl ow should match arrow on control valve. The Inlet and Outlet of other water
treatment equipment products will vary depending on the control valve brand used.
SOFTENER
SX SERIES
WELL
WATER
INCOMING
TREATED WATER
SOFT WATER
BRINE
TANK
FILTER
TO WELL PUMP
CONTROLLER
110/115V
RECEPTACLE
FEED PUMP
INJECTOR
ASSEMBLY
PRESSURE
TRANSDUCER
SOLUTION
TANK
WELL
WATER
TO MAGNETIC START
FOR WELL PUMP
FROM FLOAT SWITCH
RE-PUMP
TO
PRESSURE
SWITCH
TEST VALVE
VARIABLE SPEED / CONSTANT PRESSURE PUMP INSTALL
TANK
PRESSURE
W
ASTE DRAIN
W
ASTE DRAIN
W
ASTE DRAIN
FLOW SWITCH
CHECK VALVE
CHECK VALVE
UNTREATED WATER
FOR SPRINKLERS
OR OTHER HIGH DEMAND
SOFTENER
SX SERIES
WELL
WATER
INCOMING
TREATED WATER
SOFT WATER
BRINE
TANK
FILTER
TO WELL PUMP
CONTROLLER
110/115V
RECEPTACLE
FEED PUMP
INJECTOR
ASSEMBLY
PRESSURE
TRANSDUCER
SOLUTION
TANK
TEST VALVE
SPLIT-STREAM INSTALLATION
W
ASTE DRAIN
W
ASTE DRAIN
W
ASTE DRAIN
FLOW SWITCH
CHECK VALVE
CHECK VALVE
UNTREATED WATER
FOR SPRINKLERS
OR OTHER HIGH DEMAND
PRIMARY PRESSURE SWITCH
TANK
PRESSURE
TANK
AERATION
OPTIONAL
H
2
S
AERATOR
SYSTEM
Figure 1