SECTION 2: BEFORE INSTALLATION

Inspecting And Handling Your Filter System:

I

nspect shipping carton and the equipment for shipping damage. If damaged, notify

the transportation company and request a damage inspection. Because your fi lter
system may be shipped in more than one carton, refer to the chart to determine the total
number of cartons you should have for your particular model.
NOTE: Sulfur reduction media (generally a case of four (4) one gallon bottles; PN SS0104)
is not included as an integral part of the system, but is sold as a separate item by the
manufacturer.

Handle the media tank with care. Damage can occur if dropped or set on sharp, uneven
projections on the fl oor. Do not turn the media tank upside down. Installation must
comply with state and local laws and regulations.

MAKE SURE YOUR WATER HAS BEEN THOROUGHLY TESTED:

An analysis of your water should be made prior to the selection of your water conditioning equipment. Your dealer will generally perform this service for
you, and may send a sample to the factory for analysis and recommendations. Enter your analysis below for a permanent record.

IMPORTANT NOTE

IMPORTANT NOTE

Hydrogen sulfi de gas (H

2

S) must be tested for at the well site. For accuracy, the sample must be drawn with the pump RUNNING, and the test be com-

pleted within ONE minute after the sample is drawn.

Analysis of your Water

It is extremely important to have your water tested for the following items prior to installation of this fi lter system into your home. Record your results below
for future reference:

CONTAMINANT

YOUR WATER

Hardness

___________gpg

Iron (Fe)

___________ppm

Manganese (Mn)

___________ppm

pH

___________

Tannins (Humic Acid)

___________ppm

Hydrogen Sulfi de (H

2

S)

___________ppm

Other____________________

___________ppm

Other____________________

___________ppm

IMPORTANT NOTE

IMPORTANT NOTE

The test for hydrogen sulfi de gas (H

2

S) must be completed at the well site. For accuracy, the sample must be drawn with the pump RUNNING, and the

test be completed within ONE (1) minute after the sample is drawn.

Check Your Water Pressure And Pumping Rate

Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipment damage. Failure to check water system conditions
may result in unit failure and will void warranty:

1) Minimum water pressure required at the media tank inlet is 20 psi (138 kPa).

CAUTION

To reduce the risk associated with property damage due to water leakage:

Do not install if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds 80 psi (552 kPa), you must install a pressure limiting

valve. Contact a plumbing professional if you are uncertain how to check your water pressure.

2-1

COMPONENT

CSX100

CSX200

Media tank

-

1

Media

-

2

Feed Pump

-

1

Solution Tank & Parts

-

1

Total Cartons

1

5