11. Time of day fl ashes on and off.

A. Power has been off for more than eight (8) hours.

1. Reset the time of day.

B. SET HOUR was pressed.

1. Reset the time of day.

12. Valve stalled in backwashing.

A. Motor not operating.

1. Replace motor.

B. No power at the outlet

1. Repair outlet or use a working one.
2. Check circuit breaker at the main power box.

C. Damaged transformer.

1. Replace transformer.

D. Damaged PC board.

1. Replace PC board.

E. Broken drive gear or drive cap assembly.

1. Replace gear or drive cap assembly.

F. Broken piston retainer.

1. Replace main piston assembly.

G. Broken main piston.

1. Replace main piston assembly.

13. Valve does not regenerate automatically

when the

and

buttons are pushed.

A. Transformer unplugged.

1. Connect transformer and the PC board power

B. No power at outlet.

1. Restore or repair power source.

C. Broken drive gear or drive cap assembly.

1. Replace gear or drive cap assembly.

D. Damaged PC board.

1. Replace PC board.

14. Valve does not regenerate automatically,

but does when

and

are depressed.

A. Programming error.

1. Review programming of control valve.

B. Damaged PC board.

1. Replace PC board.