Aqua-Pure CSX200 User Manual
Page 15
4-3
USER DISPLAYS
HOW TO CHANGE THE BACKWASHING PROGRAM SETTINGS
Step 1)
Begin in normal mode and press SET +
▲ for three seconds simultaneously.
Step 2)
Set the hours for backwashing using
▲ or ▼. Press SET and proceed to step 3.
Step 3)
Set the minutes for backwashing using
▲ or ▼. Press SET and proceed to step 4.
Step 4)
Set the days for backwashing between 1 and 99. Press SET to exit Installer Displays and Settings.
GENERAL OPERATION
When operating, the system will either display the current time of day or the days remaining until the next backwashing. Use
▲ or ▼ to toggle between the
two displays. If the remaining days is at 1, the system will regenerate at the preset time.
An arrow will appear pointing to REGEN when the system calls for backwashing.
BACKWASHING MODE
When the system is regenerating, untreated water will be used. Therefore, systems are typically set to regenerate during times of low water usage—such as
when the household is asleep.
During backwashing, the arrow will point to REGEN and the display will change to Backwashing Cycle Display, indicating the time remaining. The system
automatically runs through the steps of backwashing; upon completion, treated water is ready for use.
HOW TO MANUALLY INITIATE BACKWASHING
If a system needs to be regenerated before the next scheduled time, manual backwashing can be initiated. This may be necessary during times of heavy water
usage, including house guests or heavy laundry days.
To initiate a manual backwashing at the preset delay time, press
▲ and ▼ simultaneously. Release. An arrow will point to REGEN if backwashing is expected
“tonight.” To cancel, press
▲ and ▼ simultaneously. Release.
To initiate an immediate manual backwashing, press
▲ and ▼ simultaneously for three seconds. This request cannot be cancelled. (If a softener brine tank
does not contain salt, add salt and wait at lease two hours before initiating backwashing.
HOW TO SET TIME OF DAY
Step 1)
Press SET
Step 2)
Use
▲ and ▼ to adjust the current time hour. Time display will be 12 hour with PM indicator with
60 Hz line frequency detection on power-up. Time display will be 24 hour without the PM indica-
tor with 50 Hz line frequency on power-up. Press SET and proceed to step 3.
Step 3)
Use
▲ and ▼ to adjust the current time minutes. Press SET to exit Set Time of Day.
Power Loss
If power is lost for more than 8 hours, the current time of day will need to be reset. If the system is in the
middle of backwashing upon power loss, the control will continue backwashing at the point of interruption
when power is restored.
Error Message
Contact the OEM for assistance if the display shows “E1,” “E2,” “E3” or “E4.” These messages are indications
the valve did not function properly.