Aqua-Pure CSX200 User Manual
Page 18
SECTION 6: SPECIFICATIONS AND OPERATING DATA
ITEM
CSX100
CSX200
Nominal Media Volume, cu. ft. (cu. mtr.)
1.0 (0.03)
2.0 (0.06)
Gravel Underbed, lbs (kg)
13 (5.9)
18 (8.2)
Operating Flow Rate, gpm (lpm) (Note 1)
Service (intermittent)
Peak (10 minutes max. duration)
6.0 (22.7)
10.0 (45.5)
9.0 (34.1)
13.0 (59.1)
Pressure Loss @ Flow Rates, psi (kPa)
Service
Peak
5 (0.034)
13 (0.89)
8 (0.055)
14 (0.097)
Backwash Rate, (Note 2), gpm (lpm)
5.3 (20.1)
7.5 (28.4)
Service Pipe Size, inches (cm)
1 (2.5)
1 (2.5)
Tank Diameter x Height, inches (cm)
10 x 44
(25.4 x 112)
12 x 54
(30.5 x 138)
Minimum Space Required
Width, inches (cm)
Depth, inches (cm)
Height, inches (cm)
10 (25.4)
16 (40.6)
53 (134.6)
12 (30.4)
16 (40.6)
63 (160)
Approximate Shipping Weight, lbs (kg)
163 (73.9)
271 (122.9)
Maximum operating temperatures 110°F (43.3°C); Electrical requirements 110 Volt (60 Hz); Operating pressure 20-125 psi (138-862 kPa).
Notes:
(1) For satisfactory performance, indicated durations should not be exceeded; Flow rates specifi ed are adequate for normal residential applications. This
fi lter system is not intended to treat commercial applications.
(2) Indicated pressure loss is for new systems, these losses will increase as the fi lter is used and the longer the duration since last backwashing.
6-1