NeoFox Communication Interfaces

22 013-20000-010-04-201211

Multi Point SP B0

Float

n/a

268

n/a

n/a

n/a


This is a Single Point calibration parameter. It is a copy of its counterpart from the multi-point calibration parameter
that is copied during a single point reset. It cannot be read or set through DLL function calls. It also cannot be set
through the serial protocol, but it can be read. See the

NeoFox Calibration and Measurement

engineering note and the

NeoFox manual

for more information about this parameter.


Multi Point SP B1

Float

n/a

272

n/a

n/a

n/a


This is a Single Point calibration parameter. It is a copy of its counterpart from the multi-point calibration parameter
that is copied during a single point reset. It cannot be read or set through DLL function calls. It also cannot be set
through the serial protocol, but it can be read. See the

NeoFox Calibration and Measurement

engineering note and the

NeoFox manual

for more information about this parameter.


Multi Point SP B2

Float

n/a

276

n/a

n/a

n/a


This is a Single Point calibration parameter. It is a copy of its counterpart from the multi-point calibration parameter
that is copied during a single point reset. It cannot be read or set through DLL function calls. It also cannot be set
through the serial protocol, but it can be read. See the

NeoFox Calibration and Measurement

engineering note and the

NeoFox manual

for more information about this parameter.


Multi Point SP C0

Float

n/a

280

n/a

n/a

n/a


This is a Single Point calibration parameter. It is a copy of its counterpart from the multi-point calibration parameter
that is copied during a single point reset. It cannot be read or set through DLL function calls. It also cannot be set
through the serial protocol, but it can be read. See the

NeoFox Calibration and Measurement

engineering note and the

NeoFox manual

for more information about this parameter.


Multi Point SP C1

Float

n/a

284

n/a

n/a

n/a


This is a Single Point calibration parameter. It is a copy of its counterpart from the multi-point calibration parameter
that is copied during a single point reset. It cannot be read or set through DLL function calls. It also cannot be set
through the serial protocol, but it can be read. See the

NeoFox Calibration and Measurement

engineering note and the

NeoFox manual

for more information about this parameter.


Multi Point SP C2

Float

n/a

288

n/a

n/a

n/a

This is a Single Point calibration parameter. It is a copy of its counterpart from the multi-point calibration parameter
that is copied during a single point reset. It cannot be read or set through DLL function calls. It also cannot be set
through the serial protocol, but it can be read. See the

NeoFox Calibration and Measurement

engineering note and the

NeoFox manual

for more information about this parameter.


Multi Point SP T0

Float

n/a

292

n/a

n/a

n/a

This is a Single Point calibration parameter. It is a copy of its counterpart from the multi-point calibration parameter
that is copied during a single point reset. It cannot be read or set through DLL function calls. It also cannot be set
through the serial protocol, but it can be read. See the

NeoFox Calibration and Measurement

engineering note and the

NeoFox manual

for more information about this parameter.