beautypg.com

Advanced featured – Crown Audio I-Tech HD Series User Manual

Page 17

background image

I-Tech HD Series

Power Amplifiers

I-Tech HD Series

Power Amplifiers

page 32

page 33

Operation Manual

Operation Manual

I-Tech 12000HD AC Current Draw and Thermal Dissipation:

Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.

Typical line impedance used.

Data based on both channels driven.

Line Current

120VAC

Watts Out

Per 1A

Amp Line

Current

Line Current

208VAC

Watts Out

Per 1A

Amp Line

Current

Line Current

230VAC

Watts Out

Per 1A

Amp Line

Current

Btu/hr

kcal/h

r

Idle (sleep mode)

0.9

1.1

1.0

62

212

18

3

Idle (awake)

2.0

1.8

1.6

213

726

62

5

1/8th Power Pink Noise

8 Ohms/Ch.

Typical of program material

16 Ohms Bridge

just at clip.

4 Ohms/Ch.

8 Ohms Bridge

2 Ohms/Ch.

4 Ohms Bridge

1/3rd Power Pink Noise

8 Ohms/Ch.

Typical of program material

16 Ohms Bridge

with severe clipping.

4 Ohms/Ch.

8 Ohms Bridge

2 Ohms/Ch.

4 Ohms Bridge

441

1504

379

8.3

63.6

103.3

5.1

4.7

14.6

68.8

2394

603

14.2

764

2607

657

8.7

18.1

715

2439

615

144.2

701

1370

4677

117

9

1589

5425

136

8

118.0

131.1

17.9

8.2

33.9

35.1

11.0

20.8

19.9

9.9

18.7

62.9

77.4

76.3

69.2

128.3

128.6

115.2

106.1

8.0

7.7

111.8

124.5

113.6

230VAC

142.0

Watts

Dissapite

d

Thermal Dissipatio

n

I-T12000HD

Load

120VAC

208VAC

Protection System

Your Crown amplifier provides extensive pro tection and diagnostic capabilities, including thermal level control,

fault indicators, high-pass filtering, DC protect, AC under/over volt age protection, inrush limiting, and variable-

speed fans with tachometer feedback. Microprocessor monitors fans, and signals an error via System Architect if

fans are not operating.

Thermal Level Control (TLC)

If the amplifier becomes too hot for safe opera tion, the TLC will engage the input compressor and the clip LED will

illuminate. By compress ing the input, the amplifier will not generate as much heat and will have a chance to cool

down. The degree of compression is proportional to the amount of overheating. This feature allows the show to go

on, rather than having the amplifier shut down, and only occurs in extreme situations.

Circuit Breaker

If the current draw of the amplifier exceeds safe limits, this breaker automatically disconnects the power supply

from the AC mains.

Advanced Featured

Global Switching Power Supply with PFC

Thanks to its global power supply, the I-Tech amplifier works anywhere in the world. There’s no need to reset an

AC mains voltage switch, and no need to order a special model. The amp will work and meet all specs on 100V -

240VAC, 50/60 Hz.
Crown’s Switching Power Supply minimizes the amplifier’s weight.
Typical non-switching power supplies require large, heavy transformers in order to produce the required power at

the output stage. These transformers must be large to operate at 50 to 60 Hz (standard AC supplied by the power

company).
By contrast, switching power supplies can operate with a much smaller (and lighter) trans former because they first

convert the AC up to a much higher frequency, thereby reducing waste.
Power Factor Correction (PFC) controls how your amplifier draws current from the AC mains. Instead of drawing

high-magnitude cur rent spikes that reduce the capacity of your power distro (and couple noise into other sys tem

components), PFC draws a smooth and quiet current waveform that is in phase with the mains voltage waveform.

PFC allows you to reduce the size and weight of your power distri bution and improve the performance of your

signal processors.

Color-Coded Overlay

The labels on the rear panel are color coded to group similar functions under common colors.