CONDITION: No sound, even though

the amp has power. Power LED is on with-

out flashing and the amp is receiving an input

sig nal. Signal indicator is on or flashing.
POSSIBLE REASON

• Speakers not connected.
• Open circuit due to speaker failure.

• Ready LED is off. Channel has been set to

standby mode via the software.

• Amplifier is in blackout mode. Press or

turn an Encoder to reactivate the LCD

display.

CONDITION: No input signal. Signal

indicator is not flashing even though audio is

applied, and the channel is ready.
POSSIBLE REASON

• Input signal level is very low.
• Another source is selected or routed.

• There is a short on the amplifier output. First

disconnect your speakers from the affected

channel(s) one by one to determine if one of

the loads is shorted.

CONDITION: Data indicator not flash­

ing, even though host computer

software is active.
POSSIBLE REASON:

• Cable between computer and amplifier is bro ken

or not connected.

Note: Data indicator flashes only when the amplifier

is polled for data, or is polled to see whether it is

online.

CONDITION: Yellow LINK ACTIVITY indicator in

Ethernet connector does not illuminate or flash.

POSSIBLE REASON:

• Ethernet link is broken.

CONDITION: Computer does not communicate with the

network devices.

POSSIBLE REASON:

• Incorrect wiring. See Section 3.5 letter O on network wiring.
• IP Addressing is not done correctly. Use the Network Troubleshooting

Wizard in System Architect.

CONDITION: COND indicator is off.

POSSIBLE REASON:

• There is only one conductor allowed per network system. This

indicator is lit only when the amplifier is the conductor.

• Amplifier is in blackout mode. Press or turn an Encoder to

reactivate the LCD display.