beautypg.com

Reset the high temperature limit stop (optional) – Factory Direct Hardware Hansgrohe 10406001 Axor Starck X User Manual

Page 8

background image

8

Remove the handle screw. Pull the green

high temperature limit stop straight off

the cartridge.

Reinstall the high temperature limit

stop so that the positioning pin on the

cartridge is in the hole for the desired

high temperature. The temperatures

shown on the diagram assume an

incoming cold water temperature of 50

o

F

and an incoming hot water temperature

of 140

o

F.

Test the unit. Reposition the high

temperature limit stop again if required.

Reinstall the nut cover. Reinstall the

handle screw and tighten four complete

turns. Reinstall the handle and continue

tightening the screw. Reinstall the screw

cover.

Reset the High Temperature

Limit Stop (Optional)

Use a 4 mm allen wrench to push the

gray rubber screw cover through the

hole in the handle. Loosen the handle

screw 4 complete turns. Pull the handle

off. Retrieve the screw cover.

Remove the nut cover and the handle

screw.

Center the cartridge stem.