13

ZonePRO

TM

VOLUME

ZC-6

ZC-6

– The ZC-6 is a push-button up/down input or output volume controller.

ZC-7

A

B

C

D

ZC-7

The ZC-7 is a programmable zone controller that allows control of page steering via

four momentary push buttons. The ZC-7 has 5 states: button A pressed, button B pressed,
button C pressed, button D pressed, and “no button pressed” being the 5th state.

ZC-8

A

B

C

D

A

B

C

D

SELECT

VOLUME

ZC-8

– The ZC-8 is used for combination up/down output volume control and four position

source selection control.

ZC-9

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

ZC-9

– The ZC-9 provides source selection control via an eight position rotary selector.

IN

OUT

INPUTS

RJ45 - CONNECT ONLY TO

ZONE CONTROLLER INPUT

RELAY/

SWITCH

CLOSURE

CONTROL
VOLTAGE

5-24 VDC

ZC-FIRE

– The ZC-FIRE is the interface to generic fire alarm relays. When the fire alarm

activates, the general purpose relay can typically be programmed to close if normally
open or vices-versa. The ZC-FIRE interface unit monitors the state of the relay (n.o. or
n.c.) and upon the state of change, notifies the ZonePRO to mute the outputs or load a
pre-programmed “Fire” scene. Control Voltage (5-24 VDC) can also be used for triggering the
ZC-FIRE.

The ZC-FIRE must be assigned as ID#2 and connected to the ZonePRO’s top ZC

Input connector for fire control.