7.5.7.2 Navigation on the control keypad
Editing numerical settings
m
WARNING! Changing parameter settings during running may cause a hazardous situation.
Parameter settings must not be changed during running.
a) Pushing ► button takes you into the edit mode.
As an indication, the parameter value starts to blink.
b) Two different methods are available to change values.
One is to set with ▲▼buttons till your desired value.
Another is to select desired digit and edit it. First push ► button,
the digit before decimal point will blink, then use ►◄ buttons to select
desired digit, set value with ▲ ▼ buttons.
C) Accept and exit with “reset/enter” button.
7.5.8 Storing and restoring parameters
7.5.8.1 User parameters
•
File “User parameters” is stored in inverter’s control unit.
•
User parameters should be saved after final set up.
•
The whole customized parameter set can be stored with parameter P3.3.1 by option 1(=Store user
parameters)
•
Select Option number 1, then press “Enter”
•
User parameters can be restored with parameter P3.3.1 by option 2 (=Load user parameters).
•
Select Option number 2, then press “Enter”
•
After restoring always check the motor parameters.
7.5.8.2 Factory parameters
•
File “Factory parameters” is stored in inverter’s control unit.
•
Factory parameters are saved at the factory according to the order and they should not be changed,
the values are the same as those in parameter list delivered with inverter.
•
Factory parameters can be restored with parameter P3.3.1 by option 4 (=Load factory parameters).
•
Select Option number 4, then press “Enter”
•
After restoring always check the motor parameters.