R&M Materials Handling ELECTRIC CHAIN HOISTS LoadMate Chain Hoist LM 10 Stepless User Manual
Page 14

LM10 STEPLESS I&M MANUAL/EN/11.30.2010
14/99
This document and the information contained herein, is the exclusive property of R&M Materials Handling, Inc., and represents a non-public, confidential and proprietary trade secret that
may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of R&M Materials Handling, Inc.
Copyright © (2010) R&M Materials Handling, Inc. All rights reserved.
2.7 Electricity
m
WARNING: In case of IT network, remove the filter FU1 before any operation
m
WARNING: Before any operation on the electric box, check that the hoist supply is
disconnected.
m
WARNING: An isolator switch should be installed at a maximum of 6 meters from the hoist.
2.8
Specific Instructions for Inverter
m
CAUTION: Check that the device cover is properly installed.
m
CAUTION: High voltages are present in this device. Switch the power off and after the
display turns off, wait 5 minutes before opening the cover.
m
CAUTION: Insulation resistance test with a megger multimeter requires special precautions.
m
CAUTION: Do not make any measurements inside the device when it is connected to the
main supply.
m
CAUTION: Do not touch the components on the circuit boards. Electrostatic discharge may
cause damage or destroy the IC-circuits.
m
CAUTION: Check all ventilation holes are clear and unobstructed.
m
CAUTION: Check that hot air coming from the brake resistors does not cause any danger.
m
CAUTION: It is forbidden to use radiophones or portable phones near this device with the
doors open.
m
CAUTION: Drive is not intended to be used in a low-voltage public network, which supplies
domestic premises. Radio frequency interference is expected if used in such a network.