resistance is high.

Power and function switch in “SCAN” position:

Press function change button shortly for frequency change

from either single or dual frequency signal for cable finding.

Press function change button and hold for 2 seconds, when

“VERIFY” LED lights up then you can take DC level polarity

test. Red Alligator connector clip positive wire and black

connect clip negative wire then “VERIFY” LED turns red, If

reversed the connection then “VERIFY” LED will turn to

green.

Cable mapping indicator

When performing cable mapping or connect to telecom

switching equipment for connection status detection,

number “1” to “8” LED will light up in order. The LED “G”

indicates the shielded conductor is connection or no

connection.

Wire finding and cable status LED indicator

For wire or cable finding and status indication

Cable test verify LED indicator

For testing result indication.

7MT-7025 Receiver instructions

1.

Tone tested probe

2. LED

illumination

3. Signal

indicator

4.

Volume adjustable rotary switch

5.

LED illumination power switch

6. Earphone

jack

7.

Cable mapping LED indicators

8. RJ45

socket

9.

Cable finding tested button