Newport Brass 3-1687 Virginia User Manual
Page 4
Disclaimer Regarding Brasstech Roman Tub with Hand Spray
To conform to local codes and ordinances, all Brasstech Roman tub with hand spray products should be used in concert with an
ASSE 1016 approved tempering valve to reduce the hot water supply to a safe temperature not exceeding 110°F (43°C).
Important: Water temperatures in excess 110°F (43°C) are dangerous and may cause scalding, severe injury of death!
Tempering valve should be installed and adjusted by a licensed contractor per the valve manufacturer installation instruction, and in
accordance with local codes and ordinances. In general, key characteristics to ensure a tempering valve to work best with
Brasstech Roman tub with hand spray products shall be as follows:
• Tempering valve should be used prior to the Roman tub product to reduce the hot water supply to a safe temperature.
• To ensure sufficient water flow through the tub spout, tempering valve should be capable to handle a flow rate of 10 gpm or
more.
• Tempering valve should include inlet filter washer and check valves in both the hot and cold water inlets to protect against cross
flow.
Pressure - Temperature - Flow Rate
Minimum supply pressure static: 30psi (207 kPa)
Inlet temperature: hot inlet, 120°F – 180°F (49°C – 82°C)
cold inlet, 39°F – 85°F (4°C – 29°C)
Temperature out: Field range: 80°F -120°F (27°C – 49°C), adjustable. Accurate within +/-3°F (1.7°C)
Maximum temperature: 200°F (93°C)
Maximum pressure: 150psi (10.3 bar)
Minimum flow: 0.5 gpm (1.9 lpm) @ 0.8psi (0.55 kPa)
Maximum flow: 20 gpm (76 lpm) @ 125psi (862 kPa)
*Note: Valve should be installed in a location where it is accessible for cleaning or service. Due to the effects of various water
conditions, periodic verification of outlet water temperature is required.
NWP-6889
INLET FOR HOT
WATER SUPPLY
INLET FOR COLD
WATER SUPPLY
*
TEMPERING VALVE