Rough-in Valve Installation

Recommended Installation by a Professional Plumbing Contractor

Note: Use plumbers tape or equivalent to seal all threaded joints.

Warning: To prevent severe damage to valve body, any solder/braze process must be performed a min. of 4"

from ports.

1. Install the quick connect spout shank through center hole of mounting surface. Secure with washer nut. See

Fig. 1.

2. Place washer nut on valve body. Insert body, (blue cold & red hot), through hole from below mounting sur-

face. See Fig. 1. Adjust and secure with additional nut so that the top of valve stem is at the correct height
from mounting surface.

3. Attach hot/cold valves to spout, utilizing ¾" copper pipe. See Fig. 3.

3/4” NPT

Finished Deck

Fig. 1

Washer Nut

1- 3/16”

Spout nipple to
be used with
trim installation

Fig. 2

Inlet for hot
water supply

Inlet for cold
water supply

NWP-1-677

EN-2406

REV -

1-1/4”

Quick connect
spout shank

1-1/4”

Valve body